Finck R H, Davis R J, Teng S, Goldfinger D, Ziman A F, Lu Q, Yuan S
Department of Pathology and Laboratory Medicine, David Geffen School of Medicine at UCLA, 10833 Le Conte Avenue, CHS A7-149, Box 107, Los Angeles, CA 90095, USA.
Immunohematology. 2011;27(1):1-5.
IgG antibodies coating red blood cells (RBCs) can be removed by elution procedures and their specificity determined by antibody identification studies. Although such testing is traditionally performed using the tube agglutination assay, prior studies have shown that the gel microcolumn (GMC) assay may also be used with comparable results. The purpose of this study was to compare an automated solid-phase red cell adherence (SPRCA) system with a GMC assay for the detection of antibodies eluted from RBCs. Acid eluates from 51 peripheral blood (PB) and 7 cord blood (CB) samples were evaluated by both an automated SPRCA instrument and a manual GMC assay. The concordance rate between the two systems for peripheral RBC samples was 88.2 percent (45 of 51), including cases with alloantibodies (n = 8), warm autoantibodies (n = 12), antibodies with no identifiable specificity (n = 2), and negative results (n = 23). There were six discordant cases, of which four had alloantibodies (including anti-Jka, -E, and -e) demonstrable by the SPRCA system only. In the remaining 2 cases, anti-Fya and antibodies with no identifiable specificity were demonstrable by the GMC assay only. All seven CB specimens produced concordant results, showing anti-A (n = 3), -B (n = 1), maternal anti-Jka (n = 2), or a negative result (n = 1). Automated SPRCA technology has a performance that is comparable with that of a manual GMC assay for identifying antibodies eluted from PB and CB RBCs.
包被红细胞(RBC)的IgG抗体可通过洗脱程序去除,其特异性可通过抗体鉴定研究确定。尽管传统上使用试管凝集试验进行此类检测,但先前的研究表明,凝胶微柱(GMC)试验也可使用,且结果相当。本研究的目的是比较自动固相红细胞粘附(SPRCA)系统与GMC试验在检测从RBC洗脱的抗体方面的效果。通过自动SPRCA仪器和手动GMC试验对来自51份外周血(PB)和7份脐带血(CB)样本的酸洗脱液进行了评估。两种系统对外周RBC样本的一致率为88.2%(51份中的45份),包括同种抗体(n = 8)、温自身抗体(n = 12)、特异性无法确定的抗体(n = 2)以及阴性结果(n = 23)的病例。有6例结果不一致,其中4例仅通过SPRCA系统检测到同种抗体(包括抗Jka、-E和-e)。在其余2例中,仅通过GMC试验检测到抗Fya和特异性无法确定的抗体。所有7份CB标本结果一致,显示抗A(n = 3)、-B(n = 1)、母体抗Jka(n = 2)或阴性结果(n = 1)。自动SPRCA技术在鉴定从PB和CB RBC洗脱的抗体方面的性能与手动GMC试验相当。