Suppr超能文献

适用于跑步机或自行车测力计的新型运动方案。

Novel exercise protocol suitable for use on a treadmill or a bicycle ergometer.

作者信息

Northridge D B, Grant S, Ford I, Christie J, McLenachan J, Connelly D, McMurray J, Ray S, Henderson E, Dargie H J

机构信息

Department of Cardiology, Western Infirmary, Glasgow.

出版信息

Br Heart J. 1990 Nov;64(5):313-6. doi: 10.1136/hrt.64.5.313.

Abstract

Many exercise protocols are in use in clinical cardiology, but no single test is applicable to the wide range of patients' exercise capacity. A new protocol was devised that starts at a low workload and increases by 15% of the previous workload every minute. This is the first protocol to be based on exponential rather than linear increments in workload. The new protocol (standardised exponential exercise protocol, STEEP) is suitable for use on either a treadmill or a bicycle ergometer. This protocol was compared with standard protocols in 30 healthy male volunteers, each of whom performed four exercise tests: the STEEP treadmill and bicycle protocols, a modified Bruce treadmill protocol, and a 20 W/min bicycle protocol. During the two STEEP tests the subjects' oxygen consumption rose gradually and exponentially and there was close agreement between the bicycle and the treadmill protocols. A higher proportion of subjects completed the treadmill than the bicycle protocol. Submaximal heart rates were slightly higher during the bicycle test. The STEEP protocol took less time than the modified Bruce treadmill protocol, which tended to produce plateaux in oxygen consumption during the early stages. The 20 W/min bicycle protocol does not take account of subjects' body weight and consequently produced large intersubject variability in oxygen consumption. The STEEP protocol can be used on either a treadmill or a bicycle ergometer and it should be suitable for a wide range of patients.

摘要

临床心脏病学中使用了多种运动方案,但没有一种单一测试适用于广泛的患者运动能力范围。设计了一种新方案,该方案从低工作量开始,每分钟增加前一工作量的15%。这是第一个基于工作量指数增加而非线性增加的方案。新方案(标准化指数运动方案,STEEP)适用于跑步机或自行车测力计。在30名健康男性志愿者中,将该方案与标准方案进行了比较,每位志愿者进行了四项运动测试:STEEP跑步机和自行车方案、改良布鲁斯跑步机方案以及20W/分钟自行车方案。在两项STEEP测试中,受试者的耗氧量逐渐呈指数上升,自行车和跑步机方案之间有密切的一致性。完成跑步机方案的受试者比例高于自行车方案。自行车测试期间次最大心率略高。STEEP方案比改良布鲁斯跑步机方案花费的时间少,改良布鲁斯跑步机方案在早期阶段往往会使耗氧量出现平台期。20W/分钟自行车方案没有考虑受试者的体重,因此在耗氧量方面受试者间产生了很大的变异性。STEEP方案可用于跑步机或自行车测力计,并且应该适用于广泛的患者。

相似文献

1
Novel exercise protocol suitable for use on a treadmill or a bicycle ergometer.
Br Heart J. 1990 Nov;64(5):313-6. doi: 10.1136/hrt.64.5.313.
2
The use of an exponential protocol for bicycle and treadmill exercise testing in patients with chronic cardiac failure.
Eur Heart J. 1992 Oct;13(10):1363-7. doi: 10.1093/oxfordjournals.eurheartj.a060067.
3
Impact of the exercise mode on exercise capacity: bicycle testing revisited.
Chest. 2005 Oct;128(4):2804-11. doi: 10.1378/chest.128.4.2804.
7
Evaluation of a new treadmill exercise protocol.
Chest. 1997 Jul;112(1):98-106. doi: 10.1378/chest.112.1.98.
8
Exercise intensity conversion from a bicycle ergometer to a treadmill.
J Sports Med Phys Fitness. 1991 Sep;31(3):490-3.
9
Comparison of the ramp versus standard exercise protocols.
J Am Coll Cardiol. 1991 May;17(6):1334-42. doi: 10.1016/s0735-1097(10)80144-5.
10
VO2max of cyclists from treadmill, bicycle ergometer and velodrome tests.
Eur J Appl Physiol Occup Physiol. 1983;50(2):283-9. doi: 10.1007/BF00422167.

引用本文的文献

2
ARTP statement on cardiopulmonary exercise testing 2021.
BMJ Open Respir Res. 2021 Nov;8(1). doi: 10.1136/bmjresp-2021-001121.
4
The early identification of psychosis: can lessons be learnt from cardiac stress testing?
Psychopharmacology (Berl). 2016 Jan;233(1):19-37. doi: 10.1007/s00213-015-4143-3. Epub 2015 Nov 14.
6
Exercise facilitators and barriers following participation in a community-based exercise and education program for cancer survivors.
J Exerc Rehabil. 2015 Feb 28;11(1):20-9. doi: 10.12965/jer.150183. eCollection 2015 Feb.
7
Effects of Exercise Type on Hemodynamic Responses and Cardiac Events in ACS Patients.
J Phys Ther Sci. 2014 Apr;26(4):609-14. doi: 10.1589/jpts.26.609. Epub 2014 Apr 23.
8
The effect of exercise on neuropathic symptoms, nerve function, and cutaneous innervation in people with diabetic peripheral neuropathy.
J Diabetes Complications. 2012 Sep-Oct;26(5):424-9. doi: 10.1016/j.jdiacomp.2012.05.007. Epub 2012 Jun 18.
10
Exponential protocols for cardiopulmonary exercise testing on treadmill and cycle ergometer.
Eur J Appl Physiol. 2010 Jan;108(1):167-75. doi: 10.1007/s00421-009-1183-6. Epub 2009 Sep 22.

本文引用的文献

2
Optimizing the exercise protocol for cardiopulmonary assessment.
J Appl Physiol Respir Environ Exerc Physiol. 1983 Nov;55(5):1558-64. doi: 10.1152/jappl.1983.55.5.1558.
4
Cardiovascular responses to submaximum and maximum effort cycling and running.
J Appl Physiol. 1971 Apr;30(4):457-61. doi: 10.1152/jappl.1971.30.4.457.
5
Oxygen uptake kinetics for various intensities of constant-load work.
J Appl Physiol. 1972 Sep;33(3):351-6. doi: 10.1152/jappl.1972.33.3.351.
8
Cardiac output during submaximal and maximal treadmill and bicycle exercise.
J Appl Physiol. 1970 Jul;29(1):82-6. doi: 10.1152/jappl.1970.29.1.82.
9
Disparities in ventilatory and circulatory responses to bicycle and treadmill exercise.
Br Heart J. 1974 Apr;36(4):377-82. doi: 10.1136/hrt.36.4.377.
10
Exercise testing in angina pectoris: the importance of protocol design in clinical trials.
Am Heart J. 1989 Feb;117(2):505-8. doi: 10.1016/0002-8703(89)90806-5.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验