Department of Anesthesiology and Pain Medicine, College of Medicine, Seoul National University, Seoul, Korea.
Korean J Anesthesiol. 2012 Mar;62(3):281-4. doi: 10.4097/kjae.2012.62.3.281. Epub 2012 Mar 21.
Transfusion-induced hyperkalemia can lead to cardiac arrest, especially when the patient rapidly receives a large amount of red blood cells (RBCs), previously stored for a long period of time, irradiated or both. We report on a case of application of the Continuous AutoTransfusion System (CATS) to wash RBCs, in order to lower the high potassium (K(+)) level in the packed RBCs unit, during massive transfusion following transfusion-induced hyperkalemic cardiac arrest. After the washing process using CATS, there was no more electrocardiographic abnormality or cardiac arrest due to hyperkalemia. This case emphasizes the potential risk to develop transfusion-related hyperkalemic cardiac arrest, during massive transfusion of irradiated, pre-stored RBCs. CATS can be effectively used to lower the K(+) concentration in the packed RBCs unit, especially when the risk of transfusion-induced hyperkalemia is high.
输血引起的高钾血症可导致心跳骤停,尤其是当患者快速输入大量先前长期储存、辐照或两者兼有的红细胞(RBC)时。我们报告了一个应用连续自动输血系统(CATS)来洗涤 RBC 的案例,以降低因输血引起的高钾血症性心跳骤停后大量输血时的 RBC 单位中高钾(K(+))水平。在使用 CATS 进行洗涤后,没有再出现心电图异常或因高钾血症引起的心跳骤停。该病例强调了在大量输注辐照、预先储存的 RBC 时,发生与输血相关的高钾血症性心跳骤停的潜在风险。CATS 可有效用于降低 RBC 单位中的 K(+)浓度,特别是在发生输血引起的高钾血症的风险较高时。