Zotov V M, Murashkin N I, Sirota A V
Stomatologiia (Mosk). 1990 Jul-Aug(4):51-2.
Forty-four patients fitted with fixed dentures made of stainless steel with TiN-based decorative coating were followed up for 2 years. Abrasion of the decorative coating at the site of the crown contact with the basis and clammers of plate dentures and at the site of cutting edges of frontal teeth was recorded in 11 (25 percent) subjects. Measurements of the electric potentials have revealed their essential increase in the patients fitted with dentures with TiN-based coating vs. those with dentures made of gold and steel.
对44名佩戴由不锈钢制成并带有氮化钛基装饰涂层的固定假牙的患者进行了为期2年的随访。在11名(25%)受试者中记录到,假牙冠与基托和板牙夹接触部位以及前牙切缘部位的装饰涂层出现磨损。对电位的测量结果显示,佩戴氮化钛基涂层假牙的患者与佩戴金和钢制成的假牙的患者相比,电位显著升高。