Between 2003 and 2009, 54,255 breath test sequences were performed on 129 AlcoSensor IV-XL evidential instruments in Orange County, CA. The overall mean breath alcohol concentration and standard deviation from these tests was 0.141 ± 0.051 g/210 L. Of these test sequences, 38,580 successfully resulted in two valid breath alcohol results, with 97.5% of these results agreeing within ±0.020 g/210 L of each other and 86.3% within ±0.010 g/210 L. The mean absolute difference between duplicate tests was 0.006 g/210 L with a median of 0.004 g/210 L. Of the 2.5% of duplicate test results that did not agree within ±0.020 g/210 L, 95% of these had a breath alcohol concentration of 0.10 g/210 L or greater and 77% had an alcohol concentration of 0.15 g/210 L or greater. The data indicate that the AlcoSensor IV-XL can measure a breath sample for alcohol concentration with adequate precision even amid the effects of biological variations.
2003年至2009年期间,在加利福尼亚州奥兰治县的129台AlcoSensor IV-XL证据检测仪器上进行了54255次呼气测试序列。这些测试的总体平均呼气酒精浓度和标准差为0.141±0.051 g/210L。在这些测试序列中,38580次成功得出了两个有效的呼气酒精检测结果,其中97.5%的结果相互之间的差异在±0.020 g/210L以内,86.3%在±0.010 g/210L以内。重复测试之间的平均绝对差值为0.006 g/210L,中位数为0.004 g/210L。在±0.020 g/210L范围内不一致的2.5%的重复测试结果中,95%的呼气酒精浓度为0.10 g/210L或更高,77%的酒精浓度为0.15 g/210L或更高。数据表明,即使在生物变异的影响下,AlcoSensor IV-XL也能以足够的精度测量呼气样本中的酒精浓度。