Suppr超能文献

颅颈不稳定的前向剪切和牵张试验。一项使用磁共振成像的评估。

The anterior shear and distraction tests for craniocervical instability. An evaluation using magnetic resonance imaging.

作者信息

Osmotherly Peter G, Rivett Darren A, Rowe Lindsay J

机构信息

School of Health Sciences, The University of Newcastle, Callaghan, NSW 2308, Australia.

出版信息

Man Ther. 2012 Oct;17(5):416-21. doi: 10.1016/j.math.2012.03.010. Epub 2012 May 3.

Abstract

Screening for integrity of the ligaments of the craniocervical complex has been suggested prior to the application of manual techniques to the upper cervical spine. However, most tests proposed lack validation limiting their usefulness clinically. This study examined the effect of the anterior shear test for the transverse ligament and the distraction test for the tectorial membrane in normal volunteers. MRI was performed in supine in neutral and end-range stress test positions in 16 individuals using proton density-weighted sequences and a standard head coil in a 3-T system. Measurements were made with respect to a strictly standardised protocol. The anterior shear test was assessed using changes in atlantodental interval and distance from the anterior arch of the atlas to the posterior aspect of the odontoid process. Distraction testing for the tectorial membrane was assessed by changes in basion-dental interval and by direct measurement of the tectorial membrane. Differences were compared using Wilcoxon Sign Rank tests or paired t-test depending upon each variables assessment of normality. Anterior shear testing resulted in a 0.41 mm mean increase in atlantodental interval (p = 0.03) and 0.35 mm mean increase in axial plane distance (p = 0.05). Distraction testing for the tectorial membrane resulted in a 0.64 mm increase in basion-dental interval (p < 0.01) and a 1.11 mm increase in direct ligament length measurement (p = 0.02). Reliability of measurements ranged from moderate to substantial. These results indicate that these tests produce a consistent direct effect on the transverse ligament and the tectorial membrane which is consistent with their theorised mechanism for clinical use.

摘要

在对上颈椎应用手法技术之前,有人建议对颅颈复合体韧带的完整性进行筛查。然而,大多数所提出的测试缺乏有效性验证,限制了它们在临床上的实用性。本研究在正常志愿者中检测了横韧带的前剪切试验和覆膜的牵引试验的效果。16名个体在3-T系统中使用质子密度加权序列和标准头部线圈,在仰卧位的中立位和终末范围应力测试位置进行了MRI检查。测量是按照严格标准化的方案进行的。前剪切试验通过寰齿间距的变化以及从寰椎前弓到齿突后缘的距离来评估。覆膜的牵引试验通过颅底-齿突间距的变化以及对覆膜的直接测量来评估。根据每个变量的正态性评估,使用Wilcoxon符号秩检验或配对t检验比较差异。前剪切试验导致寰齿间距平均增加0.41mm(p = 0.03),轴向平面距离平均增加0.35mm(p = 0.05)。覆膜的牵引试验导致颅底-齿突间距增加0.64mm(p < 0.01),韧带直接长度测量增加1.11mm(p = 0.02)。测量的可靠性从中度到高度不等。这些结果表明,这些测试对横韧带和覆膜产生了一致的直接影响,这与它们在临床应用中的理论机制一致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验