Department of Nuclear Medicine, Furness General Hospital, Barrow-in-Furness, UK.
Br J Radiol. 2012 Sep;85(1017):1320-6. doi: 10.1259/bjr/99497945. Epub 2012 May 9.
ROCView has been developed as an image display and response capture (IDRC) solution to image display and consistent recording of reader responses in relation to the free-response receiver operating characteristic paradigm. A web-based solution to IDRC for observer response studies allows observations to be completed from any location, assuming that display performance and viewing conditions are consistent with the study being completed. The simplistic functionality of the software allows observations to be completed without supervision. ROCView can display images from multiple modalities, in a randomised order if required. Following registration, observers are prompted to begin their image evaluation. All data are recorded via mouse clicks, one to localise (mark) and one to score confidence (rate) using either an ordinal or continuous rating scale. Up to nine "mark-rating" pairs can be made per image. Unmarked images are given a default score of zero. Upon completion of the study, both true-positive and false-positive reports can be downloaded and adapted for analysis. ROCView has the potential to be a useful tool in the assessment of modality performance difference for a range of imaging methods.
ROCView 被开发为一种图像显示和响应捕获 (IDRC) 解决方案,用于在自由响应接收者操作特性范式下进行图像显示和读者响应的一致记录。用于观察者响应研究的基于网络的 IDRC 解决方案允许在任何位置完成观察,只要显示性能和观察条件与正在完成的研究一致。该软件的简单功能允许在没有监督的情况下完成观察。ROCView 可以按要求以随机顺序显示来自多个模态的图像。注册后,观察者会被提示开始图像评估。所有数据都通过鼠标点击记录,一个用于定位 (标记),一个用于使用顺序或连续评分量表对置信度 (评分) 进行评分。每个图像最多可以进行九次“标记-评分”对。未标记的图像默认得分为零。研究完成后,可以下载并调整真实阳性和假阳性报告以进行分析。ROCView 有可能成为评估各种成像方法的模态性能差异的有用工具。