The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE).
Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients).
TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)].
Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE.
本前瞻性研究旨在探讨心电图门控 CT(ECG-gated CT)与经食管超声心动图(TEE)在主动脉人工瓣心内膜炎(PVE)患者中的检查结果是否具有一致性。
27 例连续的 PVE 患者均接受了 64 排 ECG-gated CT 和 TEE 检查,比较了两种检查结果。将影像学结果与手术结果(16 例患者进行了手术)进行比较。
TEE 提示所有患者均存在 PVE [主动脉壁增厚(n=17)、赘生物(n=13)、脓肿(n=16)、瓣叶裂(n=10)]。ECG-gated CT 在 25 例患者中呈阳性(93%)[主动脉壁增厚(n=19)、赘生物(n=7)、脓肿(n=18)、瓣叶裂(n=7)]。ECG-gated CT 与 TEE 的一致性强度[kappa(95%置信区间)]对于主动脉壁增厚[0.83(0.62-1.0)]、脓肿[0.68(0.40-0.97)]和瓣叶裂[0.75(0.48-1.0)]非常好,对于赘生物为中度[0.55(0.26-0.88)]。手术发现(脓肿、赘生物和瓣叶裂)与 ECG-gated CT [0.66(0.49-0.87)]和 TEE [0.79(0.62-0.96)]之间的一致性良好,ECG-gated CT 与 TEE 联合检查的一致性非常好[0.88(0.74-1.0)]。
我们的研究结果表明,ECG-gated CT 与 TEE 具有相当的诊断性能,可作为主动脉 PVE 患者术前评估的一种有价值的补充手段。