Gabriel Carmen Comas, Echevarria M, Rodríguez I, Serra B
Fetal Medicine Unit, Department of Obstetrics and Gynecology, Institut Universitari Dexeus, Gran Vía Carles III 71-75, 08028 Barcelona, Spain.
ScientificWorldJournal. 2012;2012:482832. doi: 10.1100/2012/482832. Epub 2011 Dec 12.
Quantitative analysis of the quality of nuchal translucency (NT) measurements.
First-trimester combined screening for Down syndrome was performed to all pregnant women attended in our Department from October 2003 to November 2009. NT was measured according to the Fetal Medicine Foundation (FMF) criteria by 20 trained obstetricians. The performance of NT measurements was retrospectively analyzed with regard to several quality control standards. Accuracy according to experience, professional profile, crown rump length (CRL) values, and FMF certification was statistically tested.
A total of 14978 NT measurements were assessed. (1) The mean operator-specific median NT-MoM values was 0,98. (2) Mean percentage of cases >95th and <5th centiles were 5,0% and 4,2%, respectively. (3) Logarithmic mean and SD of the NT MoM values were 0,00 and 0,13, respectively. (4) The DR for trisomy 21 at screening time was 90,7% for a FPR of 6,7% for standard screening strategy. (5) According to Cumulative SUM (CUSUM) figures, the performance was more acceptable in FMF-certified operators.
Overall, quality standards show optimal NT measurements in our unit. Operator experience, a dedicated profile to fetal medicine, CRL over 60 mm, and FMF certification have a significant positive impact on the quality standards.
对颈项透明层(NT)测量质量进行定量分析。
对2003年10月至2009年11月在我科就诊的所有孕妇进行孕早期唐氏综合征联合筛查。由20名经过培训的产科医生按照胎儿医学基金会(FMF)标准测量NT。根据多项质量控制标准对NT测量的表现进行回顾性分析。对根据经验、专业背景、头臀长(CRL)值和FMF认证得出的准确性进行统计学检验。
共评估了14978次NT测量。(1)特定操作者的NT-MoM值中位数的平均值为0.98。(2)NT值>第95百分位数和<第5百分位数的病例平均百分比分别为5.0%和4.2%。(3)NT MoM值的对数均值和标准差分别为0.00和0.13。(4)对于标准筛查策略,筛查时21三体的检出率(DR)为90.7%,假阳性率(FPR)为6.7%。(5)根据累积和(CUSUM)数据,FMF认证的操作者的表现更可接受。
总体而言,质量标准显示我们科室的NT测量情况最佳。操作者经验、专注于胎儿医学的专业背景、CRL超过60 mm以及FMF认证对质量标准有显著的积极影响。