[屈光参数之间的关系:球镜、柱镜和轴位]

[Relationships between refractive parameters: sphere, cylinder and axis].

作者信息

Touzeau O, Gaujoux T, Bullet J, Allouch C, Borderie V, Laroche L

机构信息

Service 5, centre hospitalier national d'ophtalmologie des Quinze-Vingts, 28, rue de Charenton, 75012 Paris, France; Inserm, institut de la vision, 17, rue Moreau, 75012 Paris, France.

出版信息

J Fr Ophtalmol. 2012 Oct;35(8):587-98. doi: 10.1016/j.jfo.2011.12.006. Epub 2012 Jun 4.

Abstract

PURPOSE

To analyze the relationships between refractive parameters as well as the relationship between fellow eyes in a normal population.

METHODS

Both subjective refraction and auto-refractometry data of 500 patients were prospectively recorded. Refraction data were analyzed on three rectangular coordinates in a dioptric space. WTR/ATR ratio of axis was quantified by the Cos2axis function. Enantiomorphism (mirror-image symmetry) between fellow eye axes was quantified by the absolute value of the difference between 180° and the sum of both axes.

RESULTS

Mean refraction and mean cylinder were -1.74D (+0.28D × 91.5°) and 0.81 ± 0.89D respectively. The spherical component had no significant influence on refractive astigmatism (r(s)≤ 0.07, P ≥ 0.07) except for high spherical ametropia. Eyes with spherical equivalent greater than 4D (in absolute value) demonstrated higher cylinder (1.15D vs 0.84D, P<0.001). Cylinder influenced the WTR/ATR ratio (r(s)=-0.25, P<0.001) and the enantiomorphism (r(s)=0.36, P<0.001). Age also influenced the WTR/ATR ratio (r(s)=0.27, P<0.001) and the enantiomorphism (r(s)=0.14, P<0.001). Axes were more likely WTR and enantiomorphic when the cylinder was high and the subject young. Oblique axes were less enantiomorphic (35.5° vs 20.6°, P<0.001) and were associated with lower cylinder (0.56D vs 0.98D, P<0.001). Correlation between fellow eyes was significant for cylinder (r(s)=0.66, P<0.001) and for spherical equivalent (r(s)=0.96, P<0.001). Gender had no significant influence on refraction (P>0.12) except for spherical equivalent (relative hyperopia of +0.17D, P=0.04 in females).

CONCLUSION

The spherical component of the refraction appears to be independent of the refractive astigmatism except for high spherical ametropia. Cylinder influences somewhat the WTR/ATR ratio of axis and the enantiomorphism. Relationships between refractive parameters are weak in comparison to the fellow eye relationships.

摘要

目的

分析正常人群中屈光参数之间的关系以及双眼之间的关系。

方法

前瞻性记录500例患者的主观验光和自动验光数据。在屈光度空间的三个直角坐标系上分析验光数据。用Cos2axis函数量化轴的顺规/逆规比率。用180°与两眼轴之和的差值的绝对值量化双眼轴之间的镜像对称(对映性)。

结果

平均屈光和平均柱镜度数分别为-1.74D(+0.28D×91.5°)和0.81±0.89D。除高度球镜屈光不正外,球镜成分对屈光性散光无显著影响(r(s)≤0.07,P≥0.07)。等效球镜度数大于4D(绝对值)的眼柱镜度数更高(1.15D对0.84D,P<0.001)。柱镜影响顺规/逆规比率(r(s)=-0.25,P<0.001)和对映性(r(s)=0.36,P<0.001)。年龄也影响顺规/逆规比率(r(s)=0.27,P<0.001)和对映性(r(s)=0.14,P<0.001)。当柱镜度数高且受试者年轻的时候,眼轴更倾向于顺规和对映性。斜轴的对映性较低(35.5°对20.6°,P<0.001),且与较低的柱镜度数相关(0.56D对0.98D,P<0.001)。双眼之间柱镜度数(r(s)=0.66,P<0.001)和等效球镜度数(r(s)=0.96,P<0.001)的相关性显著。除等效球镜度数外(女性相对远视+0.17D,P=0.04),性别对屈光无显著影响(P>0.12)。

结论

除高度球镜屈光不正外,屈光的球镜成分似乎独立于屈光性散光。柱镜对轴的顺规/逆规比率和对映性有一定影响。与双眼之间的关系相比,屈光参数之间的关系较弱。