Abstract

The aim of this study was to assess Corvis ST biomechanical indices in reference to corneal enantiomorphism. In a prospective observational cohort study, 117 eyes from 63 patients with normal or keratoconus corneas were assessed by three independent observers. In the control group (n = 62), no significant differences were observed between the three observers for all indices. The best reproducibility was obtained with pachymetry and the weakest with CBI. All indices but CBI and arc length featured COV < 10%. All indices except the PD and SSI correlated with pachymetry; all but Rad correlated with IOP. The comparison of the thinnest with the thickest corneas showed no significant differences for any index except pachymetry. In the keratoconus group (n = 55), loss of corneal enantiomorphism was confirmed for all indices except the arc length, velocity, and PD. Significant differences between both groups were found for all indices, even after adjustment for pachymetry and intraocular pressure. The CBI featured the best accuracy (92%), sensitivity (91%), and graphical relevance for keratoconus diagnosis. However, its reproducibility was weak in normal corneas and was strongly dependent on corneal thickness. The SSI was independent of corneal thickness, highly reproducible, and provided the expected enantiomorphism characteristics in both groups, making it a relevant biomarker of biomechanical corneal behavior.

摘要

本研究的目的是评估Corvis ST生物力学指标与角膜对称性的关系。在一项前瞻性观察队列研究中,由三名独立观察者对63例正常或圆锥角膜患者的117只眼睛进行评估。在对照组(n = 62)中,三名观察者之间在所有指标上均未观察到显著差异。测厚法的重复性最佳,而角膜生物力学指数(CBI)的重复性最差。除CBI和弧长外,所有指标的变异系数(COV)均<10%。除瞳孔距离(PD)和角膜表面非对称指数(SSI)外,所有指标均与角膜厚度相关;除半径(Rad)外,所有指标均与眼压相关。最薄角膜与最厚角膜的比较显示,除测厚法外,任何指标均无显著差异。在圆锥角膜组(n = 55)中,除弧长、速度和PD外,所有指标均证实角膜对称性丧失。即使在对角膜厚度和眼压进行校正后,两组之间在所有指标上仍存在显著差异。CBI在圆锥角膜诊断中具有最佳的准确性(92%)、敏感性(91%)和图形相关性。然而,其在正常角膜中的重复性较弱,且强烈依赖于角膜厚度。SSI与角膜厚度无关,具有高度重复性,并在两组中均呈现预期的对称性特征,使其成为角膜生物力学行为的相关生物标志物。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6814/9863401/1fc7f905d601/jcm-12-00690-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验