MATERIAL & METHODS: Titanium implants (n = 12), placed epicrestally in the upper jaws of three dogs, were connected with titanium (Ti) and zirconium dioxide (ZrO(2) ) abutments (horizontal mismatch of 0.4 mm) and randomly allocated in a split-mouth design either to repeated (2x) dis-/re-connection at 4 and 6 weeks (test), respectively, or left undisturbed (control). At 8 weeks, histomorphometrical measurements were made between the mucosal margin (PM), implant shoulder (IS) and the apical extension of the long junctional epithelium (aJE),-the most coronal level of bone in contact with the implant (CBI).
Repeated abutment manipulation was associated with increased mean PM-aJE and IS-CBI values at both Ti (1.82 ± 0.37-1.99 ± 0.40 mm and 0.72 ± 0.18-1.12 ± 0.60 mm) and ZrO(2) (1.90 ± 0.28-2.67 ± 0.67 mm and 0.22 ± 0.10-2.15 ± 0.77 mm) abutments at 8 weeks. These vertical dimensions were comparable at both vestibular and oral aspects. Between group comparisons, however, failed to reveal a significant difference between test and control sites.
Repeated manipulation may be associated with dimensional changes of peri-implant soft and hard tissues formed at both non-matching Ti and ZrO(2) abutments.
评估基台转换种植体中基台材料和连接/分离对软硬组织变化的影响。
将钛(Ti)和氧化锆(ZrO2)基台(水平不匹配 0.4mm)分别连接到在上颌骨牙槽嵴顶部位植入的 12 个钛种植体上,采用随机分组设计,将其分为实验组(2x 次连接/分离,分别在第 4 周和第 6 周)和对照组(不分离)。在第 8 周,在黏膜边缘(PM)、种植体肩部(IS)和长结合上皮根尖延伸(aJE)之间进行组织形态学测量,aJE 是与种植体接触的最冠方骨水平。
重复基台操作与 Ti(1.82 ± 0.37-1.99 ± 0.40mm 和 0.72 ± 0.18-1.12 ± 0.60mm)和 ZrO2(1.90 ± 0.28-2.67 ± 0.67mm 和 0.22 ± 0.10-2.15 ± 0.77mm)基台的 PM-aJE 和 IS-CBI 值增加有关,在第 8 周时,这些垂直尺寸在颊侧和舌侧都相似。然而,组间比较未能显示实验组和对照组之间有显著差异。
重复操作可能与非匹配 Ti 和 ZrO2 基台形成的种植体周围软硬组织的尺寸变化有关。