Optometry Research Group, Optics Department- University of Valencia, C/ Dr Moliner, 50, 46100 Burjassot, Spain.
Br J Ophthalmol. 2012 Aug;96(8):1099-103. doi: 10.1136/bjophthalmol-2012-301475. Epub 2012 Jun 15.
To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation.
A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured.
At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic ablation groups (p=0.06). All these groups achieved better results than the high hyperopic ablation group (p<0.001). At 50% and 10%, the best values of VA were obtained for the virgin corneas and for the low myopic and low hyperopic ablation groups (p>0.1, for both levels of contrast). Significant differences were found between these three corneal profiles and the other two corneal profiles (p<0.002 for high myopic and p<0.001 for high hyperopic, for both levels of contrasts).
The results suggest that the aberration-free IOL design gives an excellent visual performance for a range of corneal spherical aberrations that could correspond to patients with virgin corneas and patients in which the corneal spherical aberration has been slightly modified by a hyperopic or myopic laser ablation.
利用自适应光学视觉模拟评估无像差人工晶状体(IOL)在不同角膜形态患者中的视觉性能。
使用 crx1 自适应光学视觉模拟器模拟无像差 IOL 与五种角膜形态(正常角膜和低、中、高近视性切削以及低、中、高远视性切削的角膜)相结合的像差模式。评估 10 名受试者的 10 只眼,测量 100%、50%和 10%对比度下的单眼远距离视力(VA)。
在 100%对比度下,正常角膜、低中高度近视切削组和低远视切削组之间的 VA 值无差异(p=0.06)。所有这些组的结果均优于高度远视切削组(p<0.001)。在 50%和 10%对比度下,VA 的最佳值分别出现在正常角膜、低度近视和低度远视切削组(p>0.1,两种对比度水平)。这三种角膜形态与另外两种角膜形态之间存在显著差异(p<0.002 高度近视和 p<0.001 高度远视,两种对比度水平)。
这些结果表明,无像差 IOL 设计可为一系列角膜球差提供出色的视觉性能,这些球差可能对应于正常角膜患者以及角膜球差因近视或远视激光切削而略有改变的患者。