Suppr超能文献

Mitral valve disruption following percutaneous balloon valvuloplasty.

作者信息

Ramondo A, Chirillo F, Dan M, Sorbara C, Fracasso A, Mazzucco A, Rampazzo C, Isabella G, Chioin R

机构信息

Department of Cardiology, Institute of Anaesthesiology, University of Padova, Italy.

出版信息

Cathet Cardiovasc Diagn. 1990 Dec;21(4):239-44. doi: 10.1002/ccd.1810210406.

Abstract

Two cases of massive mitral regurgitation due to mitral valve disruption following percutaneous balloon valvuloplasty are reported. This severe complication occurred in two elderly women with recurrent mitral stenosis after previous surgical commissurotomy. Due to their unstable hemodynamic and clinical condition, both patients underwent emergency valve replacement. At surgery, the commissures appeared fused and heavily calcified; the chordae tendineae thickened, shortened, and fused; and the leaflets presented a large tear with sheared edges. Because the technical aspects of both procedures were unremarkable, the anatomic features of the mitral valve seemed to affect the occurrence of severe mitral regurgitation. Percutaneous balloon valvuloplasty should be therefore applied carefully to patients with prior surgical valvotomy, in whom the structural alterations of the mitral apparatus may predispose to severe valvular damage.