Suppr超能文献

在双能 CT 下互补对比剂的体内分化。

In vivo differentiation of complementary contrast media at dual-energy CT.

机构信息

Department of Radiology and Biomedical Imaging, University of California San Francisco, 505 Parnassus Ave, Box 0628, M-372, San Francisco, CA 94143-0628, USA.

出版信息

Radiology. 2012 Oct;265(1):267-72. doi: 10.1148/radiol.12120692. Epub 2012 Jul 9.

Abstract

PURPOSE

To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios.

MATERIALS AND METHODS

Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium.

RESULTS

Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase-enhanced CT scan simultaneously in a single examination.

CONCLUSION

Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo.

摘要

目的

评估使用市售临床双能 CT 扫描仪来区分两种同时给药的对比剂在体内的增强效果的可行性,这两种对比剂具有互补的 X 射线衰减率。

材料与方法

本研究获得了机构动物护理和使用委员会的批准,并遵守了美国国立卫生研究院关于实验室动物护理和使用的指南。在一组碘钨溶液体模和一只兔中进行了双能 CT 检查,该兔同时给予了静脉内碘化和口服双水杨酸铋对比剂。此外,还在一只兔静脉内给予碘钨团簇对比剂后进行了研究。对图像进行处理,生成模拟常规单能扫描外观的虚拟单光子图像,以及分离每种对比剂衰减的物质分解图像。

结果

在体模和两个活体动物模型中均清晰地分离了每一对对比剂。肠腔与血管对比剂的分离允许观察到肠壁增强,而在常规 CT 扫描中肠腔内对比剂会掩盖肠壁增强。在不同血管相的两种血管对比剂的分离使得能够在单次检查中同时获得完全配准的 CT 血管造影和静脉期增强 CT 扫描。

结论

市售临床双能 CT 扫描仪可以帮助区分体内选定的互补对比剂增强效果。

相似文献

1

引用本文的文献

2
Photon-counting computed tomography in radiology.放射学中的光子计数计算机断层扫描。
Pol J Radiol. 2024 Sep 11;89:e433-e442. doi: 10.5114/pjr/191743. eCollection 2024.
5
Spectral CT: Current Liver Applications.光谱CT:当前在肝脏方面的应用
Diagnostics (Basel). 2023 May 9;13(10):1673. doi: 10.3390/diagnostics13101673.

本文引用的文献

3
Computed tomography--old ideas and new technology.计算机断层扫描——旧观念与新技术。
Eur Radiol. 2011 Mar;21(3):510-7. doi: 10.1007/s00330-011-2056-z. Epub 2011 Jan 20.
5
Dual-energy computed tomography in pulmonary embolism.双能 CT 在肺栓塞中的应用。
Br J Radiol. 2010 Aug;83(992):707-18. doi: 10.1259/bjr/16337436. Epub 2010 Jun 15.
7
Dual-energy and low-kVp CT in the abdomen.腹部双能量与低千伏CT
AJR Am J Roentgenol. 2009 Jul;193(1):47-54. doi: 10.2214/AJR.09.2592.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验