• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[The measurement of extra vascular lung water using a thermal-sodium double indicator dilution technique in patients undergoing surgery for esophageal cancer].

作者信息

Watanabe A, Kusajima K, Kawaharada N, Komatsu K, Sugimoto S, Doi H, Tanaka A, Takeda H, Mishina H, Komatsu S

机构信息

Department of Surgery (Section 2), Sapporo Medical College, Japan.

出版信息

Nihon Kyobu Geka Gakkai Zasshi. 1990 Nov;38(11):2224-30.

PMID:2280095
Abstract

The Extra Vascular Lung Water (EVLW) was measured using the thermal sodium double indicator dilution technique in 21 patients undergoing surgery for esophageal cancer. This measurement is an important parameter in the control of the respiratory function. In the 16 cases without pulmonary complications, the preoperative EVLW was 5.3 +/- 0.2 (mean +/- SEM) ml/kg and the immediate postoperative EVLW was 4.8 +/- 0.4 ml/kg. This change was significant (p less than 0.05), but within 24 hours the EVLW returned to almost the same levels as those recorded before surgery. In only 3 cases, the EVLW were elevated beyond 7.5 ml/kg, but these high EVLW levels did not continue for more than 12 hours. Of the 5 patients with pulmonary complications, only two experienced pulmonary edema. Their preoperative EVLW levels were normal, but the immediate postoperative EVLW levels were significantly elevated beyond 10 ml/kg. These elevated levels were observed before the PaO2, the portable chest roentgenograms and the other test results changed following surgery. The high EVLW levels beyond 7.5 ml/kg continued for 72 hours after surgery. We found no correlation between the EVLW and measureable hemodynamic parameters (Cardiac Index, Pulmonary Wedge Pressure, Colloid Osmotic Pressure-Pulmonary Wedge Pressure gradient) during the observation period. In the other cases with pulmonary complications (2 cases were pneumonia, one was atelectasis with pneumonia), the changes in the EVLW levels were the same as for the cases without pulmonary complications. These results indicate that the EVLW is the optimum parameter for the control of the respiratory function and early diagnosis of pulmonary edema after surgery for esophageal cancer.

摘要

相似文献

1
[The measurement of extra vascular lung water using a thermal-sodium double indicator dilution technique in patients undergoing surgery for esophageal cancer].
Nihon Kyobu Geka Gakkai Zasshi. 1990 Nov;38(11):2224-30.
2
[The change of extra vascular lung water volume in patients undergoing surgery for esophageal cancer].
Nihon Geka Gakkai Zasshi. 1991 Mar;92(3):266-75.
3
[Extravascular lung water in patients after cardiac surgery].心脏手术后患者的血管外肺水
Nihon Kyobu Geka Gakkai Zasshi. 1993 Mar;41(3):389-95.
4
[Accuracy and clinical problems involved in the measurements of extravascular lung water, using the thermal-sodium double indicator dilution technique].[采用热-钠双指示剂稀释技术测量血管外肺水所涉及的准确性及临床问题]
Kokyu To Junkan. 1991 Jan;39(1):63-6.
5
[Study on changes in extravascular lung water during early postoperative periods in thoracic esophageal cancer--with special emphasis on their relation to postoperative renal function].
Nihon Kyobu Geka Gakkai Zasshi. 1990 Mar;38(3):442-56.
6
[Studies on pre- and postoperative extravascular lung water changes in patients with esophageal cancer].
Nihon Geka Gakkai Zasshi. 1983 Apr;84(4):310-20.
7
[Extravascular lung water content following thoracic vagotomy. Experimental investigations in relation to the cause of pulmonary complications after surgery for esophageal cancer].[胸段迷走神经切断术后血管外肺水含量。与食管癌手术后肺部并发症原因相关的实验研究]
Nihon Geka Gakkai Zasshi. 1984 Feb;85(2):119-31.
8
[Measurement of extravascular lung water by double-indicator dilution method amd its clinical assessment].[双指示剂稀释法测定血管外肺水及其临床评估]
Nihon Geka Gakkai Zasshi. 1984 Nov;85(11):1418-25.
9
[Comparison of single-indicator thermodilution versus gravimetric measurement in determination of extra-vascular lung water in dogs with acute respiratory distress syndrome].[单指标热稀释法与重量法在急性呼吸窘迫综合征犬血管外肺水测定中的比较]
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue. 2006 Jun;18(6):327-30.
10
Extravascular lung water to blood volume ratios as measures of pulmonary capillary permeability in nonseptic critically ill patients.非脓毒症危重症患者肺血管外水与血容量比值作为肺毛细血管通透性的测量指标。
J Crit Care. 2010 Mar;25(1):16-22. doi: 10.1016/j.jcrc.2009.02.009. Epub 2009 May 8.