A comprehensive search of studies describing bisphenol A (BPA) concentrations in drinking water and source waters (i.e., surface water and groundwater) was conducted to evaluate the relevance of drinking water as a source of human exposure and risk. Data from 65 papers were evaluated from North America (31), Europe (17), and Asia (17). The fraction of drinking water measurements reported as less than the detection limit is high; 95%, 48%, and 41%, for North America, Europe, and Asia, respectively. The maximum quantified (in excess of the detection limit) BPA concentrations from North America, Europe, and Asia are 0.099 μg/l, 0.014 μg/l, and 0.317 μg/l. The highest quantified median and 95th percentile concentrations of BPA in Asian drinking water are 0.026 μg/l and 0.19 μg/l, while high detection limits restricted the determination of representative median and 95th percentile concentrations in North America and Europe. BPA in drinking water represents a minor component of overall human exposure, and compared with the lowest available oral toxicity benchmark of 16 μg/kg-bw/day (includes an uncertainty factor of 300) gives margins of safety >1100. Human biomonitoring data indicate that ingestion of drinking water represents <2.8% of the total intake of BPA.
进行了一项全面的研究搜索,描述了饮用水和水源(即地表水和地下水)中的双酚 A(BPA)浓度,以评估饮用水作为人类暴露和风险来源的相关性。评估了来自北美(31 篇)、欧洲(17 篇)和亚洲(17 篇)的 65 篇论文的数据。报告的饮用水测量值低于检测限的比例很高;分别为 95%、48%和 41%,用于北美、欧洲和亚洲。来自北美的饮用水中 BPA 的最大定量(超过检测限)浓度为 0.099μg/l,欧洲为 0.014μg/l,亚洲为 0.317μg/l。亚洲饮用水中 BPA 的最高定量中位数和 95%分位数浓度分别为 0.026μg/l 和 0.19μg/l,而高检测限限制了北美的代表中位数和 95%分位数浓度的确定和欧洲。饮用水中的 BPA 仅占人类暴露总量的一小部分,与最低可用的口服毒性基准值 16μg/kg-bw/day(包括 300 的不确定因素)相比,安全裕度>1100。人体生物监测数据表明,饮用水的摄入量占 BPA 总摄入量的<2.8%。