Aarli Bernt Bøgvald, Eagan Tomas Mikal Lind, Ellingsen Ivar, Bakke Per Sigvald, Hardie Jon Andrew
Department of Thoracic Medicine, Haukeland University Hospital, Bergen, Norway.
Clin Respir J. 2013 Jul;7(3):245-52. doi: 10.1111/j.1752-699X.2012.00312.x. Epub 2012 Aug 20.
A new application for the forced oscillation technique (FOT) has been described by Dellaca et al. using sinusoidal pressure variations at 5 Hz to detect expiratory flow limitation by measuring the within-breath reactance [termed difference between inspiratory and expiratory X5 (DX5)]. Few studies have been performed on respiratory phase differences in the elderly.
Our aim was to present reference values for within-breath impedance measurements and to examine how the earlier mentioned method performs in a study population of asymptomatic elderly.
An age- and sex-stratified random sample was drawn from the elderly population of Bergen, Norway. Among the healthy non-smoking responders from a postal questionnaire study, 148 were selected to perform FOT measurements using an impulse oscillometry system (IOS). Seventy five of these participants had a normal spirometry and were able to perform at least two valid FOT measurements. Predictive equations for men and women were created for FOT parameters by linear multiple regression analysis. DX5 was calculated from the within-breath variation of reactance at 5 Hz.
RESULTS/CONCLUSION: This study presents reference values for whole-breath and within-breath impedance parameters in asymptomatic elderly aged >70 years using the IOS method. We found higher resistance measurements than what is reported in previous studies and significantly larger frequency dependence.
Dellaca等人描述了强迫振荡技术(FOT)的一种新应用,即使用5Hz的正弦压力变化,通过测量呼吸内电抗[称为吸气和呼气X5(DX5)之间的差异]来检测呼气流量受限。关于老年人呼吸相位差异的研究很少。
我们的目的是给出呼吸内阻抗测量的参考值,并研究上述方法在无症状老年人研究人群中的表现。
从挪威卑尔根的老年人群中抽取了一个按年龄和性别分层的随机样本。在一项邮政问卷调查研究中的健康非吸烟应答者中,选择了148人使用脉冲振荡法系统(IOS)进行FOT测量。其中75名参与者肺活量测定正常,能够进行至少两次有效的FOT测量。通过线性多元回归分析为FOT参数创建了男性和女性的预测方程。DX5是根据5Hz时电抗的呼吸内变化计算得出的。
结果/结论:本研究使用IOS方法给出了70岁以上无症状老年人全呼吸和呼吸内阻抗参数的参考值。我们发现阻力测量值高于先前研究报告的值,且频率依赖性明显更大。