Suppr超能文献

一项评估用于脉冲振荡法系统的澳大利亚预测方程的试点研究。

A pilot study to evaluate Australian predictive equations for the impulse oscillometry system.

作者信息

Newbury Wendy, Crockett Alan, Newbury Jonathan

机构信息

Discipline of General Practice, School of Population Health and Clinical Practice, University of Adelaide, Adelaide, Australia.

出版信息

Respirology. 2008 Nov;13(7):1070-5. doi: 10.1111/j.1440-1843.2008.01375.x. Epub 2008 Aug 10.

Abstract

BACKGROUND AND OBJECTIVE

Impulse oscillometry (IOS) measures respiratory function during normal breathing by transmitting mixed frequency rectangular pressure impulses down the airways and measuring the resultant pressure and flow relationships, which describe the mechanical parameters of the lungs. Respiratory impedance and its components, airways resistance and reactance, at a range of frequencies from 0.1 to 150 Hz are calculated by computer analysis. The IOS software generates predictive normal values for each of the parameters measured, including total airway resistance (R5), proximal airway resistance (R20) and peripheral capacitive reactance (X5). However, these values are based on German data and no other Caucasian data or Australian normative data exist.

METHODS

This was a cross-sectional study of over 100 community dwelling adults, with about 10 men and 10 women per 10-year cohort. Inclusion criteria were age between 25 and 74 years and apparently good respiratory health. Exclusion criteria were smoking, asthma and acute or chronic respiratory disease. IOS and spirometry were performed on all participants.

RESULTS

Australian predictive normal equations were generated and compared with current published equations. The IOS parameters were correlated with the spirometric data. Results were analysed by gender, age, height and weight, and compared with the predicted normal values for each parameter provided by the German manufacturer of the IOS instrument.

CONCLUSIONS

A preliminary set of Australian predictive equations have been produced for the IOS. These have been compared with international equations. IOS has potential applications in a range of respiratory diseases and in population screening for occupational health assessment.

摘要

背景与目的

脉冲振荡法(IOS)通过向气道发送混合频率矩形压力脉冲并测量由此产生的压力和流量关系来测量正常呼吸过程中的呼吸功能,这些关系描述了肺部的力学参数。通过计算机分析计算出0.1至150 Hz范围内的呼吸阻抗及其组成部分,即气道阻力和电抗。IOS软件会生成所测量的每个参数的预测正常值,包括总气道阻力(R5)、近端气道阻力(R20)和外周电容电抗(Xꞏ)。然而,这些值是基于德国数据得出的,不存在其他高加索人群数据或澳大利亚的规范数据。

方法

这是一项针对100多名社区居住成年人的横断面研究,每10年年龄组中约有10名男性和10名女性。纳入标准为年龄在25至74岁之间且呼吸健康状况明显良好。排除标准为吸烟、哮喘以及急性或慢性呼吸道疾病。对所有参与者进行IOS和肺量计检查。

结果

生成了澳大利亚的预测正常方程,并与当前已发表的方程进行比较。IOS参数与肺量计数据相关。按性别、年龄、身高和体重对结果进行分析,并与IOS仪器德国制造商提供的每个参数的预测正常值进行比较。

结论

已为IOS生成了一组初步的澳大利亚预测方程。已将这些方程与国际方程进行比较。IOS在一系列呼吸道疾病以及职业健康评估的人群筛查中具有潜在应用。