Department of Radiology, University of Washington, Seattle, Washington, USA.
Head Neck. 2013 Jul;35(7):923-9. doi: 10.1002/hed.23051. Epub 2012 Aug 6.
Dynamic contrast-enhanced (DCE) MR perfusion imaging allows assessment of vascular density and integrity of tumors. The purpose of this study was to determine the diagnostic efficacy of time intensity curve analysis on DCE MRI for characterization of head and neck tumors.
Twenty patients underwent T1-weighted fast field echo DCE MRI with temporal resolution of 2.6 seconds. In total, 100 dynamic phases covering 20 slices were obtained in 4.5 minutes. Time to peak (TTP), relative maximum enhancement (RME) ratio, and relative washout ratio (RWO) were calculated.
Malignant tumors had a significantly lower RME (p = .025) and prolonged TTP with lower RWO than benign lesions. Postradiation changes had a significantly longer TTP (p = .024) and lower RWO (p = .007) than did postradiation recurrent tumors. Receiver operating characteristic (ROC) analysis revealed RWO had highest accuracy (area under the curve [AUC] = 1.0).
DCE MR perfusion imaging provides pivotal information regarding microcirculation, potentially improves differentiation of malignant tumor from postradiation changes.
动态对比增强(DCE)磁共振灌注成像是评估肿瘤血管密度和完整性的一种方法。本研究旨在探讨 DCE MRI 时间强度曲线分析对头颈部肿瘤的诊断效能。
20 例患者接受 T1 加权快速场回波 DCE MRI 检查,时间分辨率为 2.6 秒。在 4.5 分钟内获得了总共 20 个层面的 100 个动态期。计算达峰时间(TTP)、相对最大强化(RME)比和相对洗脱率(RWO)。
恶性肿瘤的 RME 明显低于良性病变(p =.025),TTP 延长,RWO 降低。放射性改变的 TTP 明显长于放射性复发性肿瘤(p =.024),RWO 降低(p =.007)。受试者工作特征(ROC)分析显示 RWO 具有最高的准确性(曲线下面积[AUC] = 1.0)。
DCE MR 灌注成像可提供有关微循环的重要信息,有助于提高对恶性肿瘤与放射性改变的鉴别诊断能力。