Suppr超能文献

使用脉搏血氧饱和度仪评估牙髓活力:一项系统评价和荟萃分析。

Evaluation of Pulp Vitality Using Pulse Oximetry: A Systematic Review and Meta-analysis.

作者信息

Sabharwal Ritu J, Dhull Kanika S, Dutta Brahmananda, Devraj Indira M, Surana Pratik, Misra Adrish, Gupta Aditi

机构信息

Department of Pedodontics and Preventive Dentistry, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology (KIIT) Deemed to be University, Bhubaneswar, Odisha, India.

Department of Pediatric and Preventive Dentistry, JSS Dental College and Hospital, JSS University, Mysuru, Karnataka, India.

出版信息

Int J Clin Pediatr Dent. 2025 Apr;18(4):479-486. doi: 10.5005/jp-journals-10005-3107. Epub 2025 May 19.

Abstract

OBJECTIVE

The present investigation was intended to compare the accuracy of diagnosis of pulse oximetry (PO) for diagnosis of pulpal pathologies.

METHODS

The present review's protocol has been registered under PROSPERO (530723) and follows the PRISMA-DTA checklist. Relevant databases were searched to ascertain PO's diagnostic capability for evaluating pulp status. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to assess the quality of all the included studies through Review Manager (RevMan ver. 5.3). Using Meta-Disk 1.4 software, a meta-analysis was performed to ascertain the pooled sensitivity and specificity. The additional investigations included summary receiver operating characteristics (SROC) with area under the curve (AUC), diagnostic odds ratio (DOR), positive likelihood ratio (PLR/+LR), and negative likelihood ratio (NLR/-LR).

RESULTS

Seven studies in all were selected for qualitative synthesis and meta-analysis. All of the examined studies showed a low risk of bias, or ROB. The diagnostic potential of PO was compared with conventional pulp vitality and sensitivity tests, including the electric pulp test (EPT), spray, rubber cups, cold, and heat tests. The meta-analysis revealed a pooled sensitivity of 0.92 (CI 0.35-1.00) and a pooled specificity of 0.08 (CI 0.00-0.63), with a +PLR of 0.95 (0.55-1.65), -NLR of 1.01 (0.22-4.64), and a DOR of 0.94 (0.11-8.48). The total diagnostic accuracy (AUC) was 0.62, indicating that PO can detect the target condition with moderate to good accuracy.

CONCLUSION

When compared to traditional methods, PO is a dependable, superior, and effective diagnostic tool with high diagnostic efficacy for detecting the target condition.

HOW TO CITE THIS ARTICLE

Sabharwal RJ, Dhull KS, Dutta B, . Evaluation of Pulp Vitality Using Pulse Oximetry: A Systematic Review and Meta-analysis. Int J Clin Pediatr Dent 2025;18(4):479-486.

摘要

目的

本研究旨在比较脉搏血氧饱和度仪(PO)诊断牙髓病变的准确性。

方法

本综述方案已在国际前瞻性系统评价注册库(PROSPERO,注册号530723)登记,并遵循PRISMA-DTA清单。检索相关数据库以确定PO评估牙髓状态的诊断能力。使用诊断准确性研究质量评估工具2(QUADAS-2)通过Review Manager(RevMan 5.3版)评估所有纳入研究的质量。使用Meta-Disk 1.4软件进行荟萃分析,以确定合并敏感性和特异性。其他分析包括总结性接受者操作特征曲线(SROC)及其曲线下面积(AUC)、诊断比值比(DOR)、阳性似然比(PLR/+LR)和阴性似然比(NLR/-LR)。

结果

共选择7项研究进行定性综合分析和荟萃分析。所有纳入研究均显示低偏倚风险(ROB)。将PO的诊断潜力与传统牙髓活力和敏感性测试进行比较,包括牙髓电活力测试(EPT)、喷雾、橡皮杯、冷诊和热诊。荟萃分析显示合并敏感性为0.92(95%CI 0.35 - 1.00),合并特异性为0.08(95%CI 0.00 - 0.63),阳性似然比为0.95(0.55 - 1.65),阴性似然比为1.01(0.22 - 4.64),诊断比值比为0.94(0.11 - 8.48)。总诊断准确性(AUC)为0.62,表明PO检测目标疾病的准确性为中度至良好。

结论

与传统方法相比,PO是一种可靠、优越且有效的诊断工具,对检测目标疾病具有较高的诊断效能。

如何引用本文

Sabharwal RJ, Dhull KS, Dutta B, 等。脉搏血氧饱和度仪评估牙髓活力:一项系统评价和荟萃分析。《国际临床儿科牙科学杂志》2025;18(4):479 - 486。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2f44/12131048/07e9329b1e7e/ijcpd-18-4-479-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验