Epidemiology of Emerging Diseases Unit, Institut Pasteur, Paris, France.
J Hosp Infect. 2013 Feb;83(2):99-106. doi: 10.1016/j.jhin.2012.07.014. Epub 2012 Sep 13.
Appropriate endovaginal/rectal ultrasound transducer disinfection has been an ongoing and vexed question in gynaecology, obstetrics and urology. However, the routine use of probe covers followed by low-level disinfection (wipes/spray) is usually applied between patients in some countries (e.g. France).
To perform a systematic review and meta-analysis of the scientific literature in order to identify case reports of contamination following endovaginal/rectal probe use, and to estimate the infection prevalence related to the use of these probes in common daily practice.
Systematic review and meta-analysis.
From the 867 potentially eligible references, 32 articles were finally included. Very few cases with an established route of contamination had been reported. Indeed, apart from occurrence of outbreaks, it is difficult if not impossible to detect viral contamination through the use of endovaginal/rectal ultrasound probes. However, there was a pooled prevalence of 12.9% (95% confidence interval: 1.7-24.3) for pathogenic bacteria, and 1.0% (0.0-10.0) for frequently occurring virus (human papillomavirus, herpes simplex virus, and cytomegalovirus) for endovaginal/rectal probes, both after low-level disinfection. The pooled prevalence of infected patients after transrectal ultrasound and guided biopsies was estimated to be 3.1% (1.6-4.3).
There appears to be a risk of transmitting bacterial or viral infections via endovaginal/rectal ultrasound transducer, and the present meta-analysis provides an estimate of this risk. Further research with sophisticated modelling is warranted to quantify the risk.
阴道/直肠超声探头的适当消毒一直是妇科、产科和泌尿科的一个持续存在且令人困扰的问题。然而,在一些国家(如法国),通常在患者之间使用探头套,并随后进行低水平消毒(擦拭/喷雾)。
对科学文献进行系统回顾和荟萃分析,以确定阴道/直肠探头使用后污染的病例报告,并估计这些探头在日常实践中的使用相关感染率。
系统回顾和荟萃分析。
从 867 篇潜在合格文献中,最终纳入 32 篇文章。仅有少数有明确污染途径的病例报告。事实上,除了暴发的发生,通过阴道/直肠超声探头很难(如果不是不可能)检测到病毒污染。然而,在经过低水平消毒后,致病性细菌的总患病率为 12.9%(95%置信区间:1.7-24.3),常见病毒(人乳头瘤病毒、单纯疱疹病毒和巨细胞病毒)的患病率为 1.0%(0.0-10.0)。对于阴道/直肠探头,这两种情况均在低水平消毒后发生。经直肠超声和引导活检后感染患者的总患病率估计为 3.1%(1.6-4.3)。
通过阴道/直肠超声探头似乎存在传播细菌或病毒感染的风险,本荟萃分析提供了对这种风险的估计。需要进一步进行复杂建模的研究来量化风险。