Suppr超能文献

针对促肾上腺皮质激素试验的特异性血清皮质醇反应:气相色谱-质谱法与五种自动化免疫分析法的比较。

Method-specific serum cortisol responses to the adrenocorticotrophin test: comparison of gas chromatography-mass spectrometry and five automated immunoassays.

机构信息

Department of Medical Biochemistry and Immunology, University Hospital of Wales, Cardiff, UK.

出版信息

Clin Endocrinol (Oxf). 2013 May;78(5):673-80. doi: 10.1111/cen.12039.

Abstract

OBJECTIVE

The serum cortisol response to the adrenocorticotrophin (ACTH) test is known to vary significantly by assay, but lower reference limits (LRL) for this response have not been established by the reference gas chromatography-mass spectrometry (GC-MS) method or modern immunoassays. We aimed to compare the normal cortisol response to ACTH stimulation using GC-MS with five widely used immunoassays.

DESIGN, PATIENTS AND MEASUREMENTS: An ACTH test (250 μg iv ACTH1-24 ) was undertaken in 165 healthy volunteers (age, 20-66 years; 105 women, 24 of whom were taking an oestrogen-containing oral contraceptive pill [OCP]). Serum cortisol was measured using GC-MS, Advia Centaur (Siemens), Architect (Abbott), Modular Analytics E170 (Roche), Immulite 2000 (Siemens) and Access (Beckman) automated immunoassays. The estimated LRL for the 30 min cortisol response to ACTH was derived from the 2·5th percentile of log-transformed concentrations.

RESULTS

The GC-MS-measured cortisol response was normally distributed in males but not females, with no significant gender difference in baseline or post-ACTH cortisol concentration. Immunoassays were positively biased relative to GC-MS, except in samples from women on the OCP, who showed a consistent negative bias. The LRL for cortisol was method-specific [GC-MS: 420 nm; Architect: 430 nm; Centaur: 446 nm; Access 459 nm; Immulite (2000) 474 nm] and, for the E170, also gender-specific (female: 524 nm; male 574 nm). A separate LRL is necessary for women on the OCP.

CONCLUSIONS

Normal cortisol responses to the ACTH test are influenced significantly by assay and oestrogen treatment. We recommend the use of separate reference limits in premenopausal women on the OCP and warn users that cortisol measurements in this subgroup are subject to assay interference.

摘要

目的

促肾上腺皮质激素(ACTH)试验的血清皮质醇反应已知因检测方法而有很大差异,但这种反应的较低参考限值(LRL)尚未通过参考气相色谱-质谱法(GC-MS)或现代免疫测定法确定。我们旨在比较使用 GC-MS 与五种常用免疫测定法测定 ACTH 刺激下的正常皮质醇反应。

设计、患者和测量:165 名健康志愿者(年龄 20-66 岁;105 名女性,其中 24 名正在服用含雌激素的口服避孕药 [OCP])接受了 ACTH 试验(250μg iv ACTH1-24)。使用 GC-MS、Advia Centaur(西门子)、Architect(雅培)、Modular Analytics E170(罗氏)、Immulite 2000(西门子)和 Access(贝克曼)自动化免疫测定法测量血清皮质醇。从对数转换浓度的第 2.5 个百分位数得出 30 分钟 ACTH 皮质醇反应的估计 LRL。

结果

GC-MS 测量的皮质醇反应在男性中呈正态分布,但在女性中则不然,基线或 ACTH 后皮质醇浓度无明显性别差异。免疫测定法相对于 GC-MS 呈正偏,除了服用 OCP 的女性样本外,后者显示出一致的负偏。皮质醇的 LRL 因方法而异[GC-MS:420nm;Architect:430nm;Centaur:446nm;Access 459nm;Immulite(2000)474nm],对于 E170,也因性别而异(女性:524nm;男性 574nm)。服用 OCP 的女性需要单独的 LRL。

结论

ACTH 试验的正常皮质醇反应受到检测方法和雌激素治疗的显著影响。我们建议在服用 OCP 的绝经前妇女中使用单独的参考限值,并警告用户,该亚组中的皮质醇测量受到检测干扰。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验