Suppr超能文献

使用 3D PET 和正常数据库解读的低剂量铷-82 心肌灌注成像检测冠状动脉疾病的准确性。

Accuracy of low-dose rubidium-82 myocardial perfusion imaging for detection of coronary artery disease using 3D PET and normal database interpretation.

机构信息

The National Cardiac PET Centre and Cardiac Research Methods Centre, Division of Cardiology, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON K1Y 4W7, Canada.

出版信息

J Nucl Cardiol. 2012 Dec;19(6):1135-45. doi: 10.1007/s12350-012-9621-y. Epub 2012 Sep 21.

Abstract

BACKGROUND

Our aim was to develop a normal database to be used for quantification of myocardial perfusion and diagnosis of "obstructive coronary artery disease" (CAD) using low-dose rubidium-82 three-dimensional (3D) positron emission tomography (PET)-CT.

METHODS

From a record of 1,501 patients, 77 were identified as having low-likelihood (LLK) of CAD. Forty LLK patients were used to construct a normal database using 4DM-PET, the remainder used for validation of normalcy. A group of 70 patients with CAD who had invasive coronary angiography and PET-CT were used to evaluate the accuracy of the database for detecting CAD using the sum-stress-score. The effect of clinical exclusion criteria and the inclusion of LLK patients were evaluated.

RESULTS

The normal database for CAD detection had a normalcy rate of 95%. Sensitivity was 100% for detecting patients with either 50% or 70% stenosis. Optimal specificity was 87% for either 50% or 70% stenosis. For localizing disease at 50% stenosis in the left anterior descending, left circumflex, and right coronary artery, sensitivity ranged from 59% to 68%, while specificity was maintained at 87-89%. Similarly, at 70% stenosis, sensitivity ranged from 64% to 79%, and specificity from 87% to 91%.

CONCLUSIONS

A normal database containing the relative perfusion scores of patients with LLK of CAD can be used to accurately diagnose obstructive coronary disease using low-dose Rb-82 with 3D PET-CT imaging.

摘要

背景

我们的目的是开发一个正常数据库,用于使用低剂量放射性铷-82 三维(3D)正电子发射断层扫描(PET)-CT 对心肌灌注进行量化和诊断“阻塞性冠状动脉疾病”(CAD)。

方法

从 1501 名患者的记录中,确定了 77 名患者 CAD 的可能性较低(LLK)。使用 4DM-PET 构建了一个正常数据库,其中 40 名 LLK 患者用于构建正常数据库,其余患者用于验证正常性。使用侵入性冠状动脉造影和 PET-CT 评估了一组 70 名 CAD 患者,以评估数据库检测 CAD 的准确性,方法是使用总应激评分。评估了临床排除标准和纳入 LLK 患者的影响。

结果

CAD 检测的正常数据库的正常率为 95%。对于 50%或 70%狭窄的患者,检测的敏感性为 100%。对于 50%或 70%狭窄,最佳特异性为 87%。对于左前降支、左旋支和右冠状动脉 50%狭窄的病变定位,敏感性范围为 59%至 68%,特异性保持在 87%至 89%。同样,在 70%狭窄时,敏感性范围为 64%至 79%,特异性为 87%至 91%。

结论

包含 CAD 的 LLK 患者相对灌注评分的正常数据库可用于使用低剂量 Rb-82 和 3D PET-CT 成像准确诊断阻塞性冠状动脉疾病。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验