NewVision Clinics, Melbourne, Australia.
J Cataract Refract Surg. 2012 Nov;38(11):1978-88. doi: 10.1016/j.jcrs.2012.07.026. Epub 2012 Sep 23.
To derive a method of quantifying corneal topographic astigmatism (CorT) that accurately represents manifest refractive cylinder.
Private practice, Melbourne, Australia.
Retrospective study.
Axial power measurements obtained using topography in right eyes and left eyes were analyzed. For each Placido ring, an astigmatism value was calculated. The ring astigmatism values were combined via vector summation to create a new measure termed CorT. This parameter was assessed against other commonly used measures of corneal astigmatism using the ocular residual astigmatism (ORA) and its standard deviation (SD) on how closely each measure matched manifest refractive cylinder. The flat meridian of the CorT can also be used to conceptually divide the cornea into 2 hemidivisions and a CorT value subsequently calculated for each hemidivision of the cornea.
The CorT was assessed against other commonly used measures of corneal astigmatism using the ORA (0.62 diopters [D] ± 0.33 [SD]) and had better correlation with manifest refractive cylinder than manual keratometry (K) (ORA 0.68 ± 0.38 D), simulated K (ORA 0.70 ± 0.35 D), corneal wavefront (ORA 0.74 ± 0.36 D), and paraxial curvature matching (ORA 0.85 ± 0.48 D). The SD of the ORA for CorT was significantly less than the other measures of astigmatism (P<.001).
An alternative measure of corneal astigmatism, known as CorT, corresponded better to manifest refractive cylinder than other commonly used measures. A hemidivisional CorT can also represent the nonorthogonal asymmetrical astigmatism in irregular corneas.
Dr. Alpins and Mr. Stamatelatos have a financial interest in the ASSORT software program used to support the planning and analysis of astigmatic correction. Dr. Ong is an employee of ASSORT.
提出一种准确表示角膜散光的角膜地形学散光(CorT)量化方法。
澳大利亚墨尔本的私人诊所。
回顾性研究。
分析右眼和左眼的地形轴向功率测量值。为每个普拉西多环计算一个散光值。通过向量求和将环散光值组合起来,创建一个新的参数,称为 CorT。通过比较角膜散光的其他常用测量值,评估该参数与眼球残余散光(ORA)及其标准差(SD)之间的关系,以了解每个测量值与角膜散光的匹配程度。CorT 的平子午线也可用于将角膜概念性地分为两个半区,然后计算每个角膜半区的 CorT 值。
用 ORA(0.62 屈光度[D]±0.33[SD])评估 CorT 与角膜散光的其他常用测量值的相关性,与手动角膜曲率计(K)(ORA 0.68±0.38 D)、模拟 K(ORA 0.70±0.35 D)、角膜波前(ORA 0.74±0.36 D)和准轴曲率匹配(ORA 0.85±0.48 D)相比,CorT 与角膜散光的相关性更好。CorT 的 ORA 标准差明显小于其他散光测量值(P<.001)。
一种新的角膜散光测量方法,称为 CorT,与其他常用的测量方法相比,更能与角膜散光相吻合。角膜的半分区 CorT 也可以表示不规则角膜的非正交不对称散光。
Alpins 博士和 Stamatelatos 先生对 ASSORT 软件程序有经济利益,该程序用于支持散光矫正的规划和分析。Ong 博士是 ASSORT 的员工。