Suppr超能文献

一种支持即刻负重全牙弓修复的新型种植体设计的宏观和微观评估。

Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

作者信息

Tetè Stefano, Zizzari Vincenzo, De Carlo Alessandro, Sinjari Bruna, Gherlone Enrico

机构信息

Department of Medical, Oral and Biotechnological Sciences, "G. d'Annunzio" University, Chieti, Italy.

出版信息

Ann Stomatol (Roma). 2012 Apr;3(2):44-50. Epub 2012 Aug 9.

Abstract

The purpose of this study is to evaluate macroscopic and microscopic appearance of a new implant design, with particular emphasis given to the type of prosthesis connection. Two dental implants of the same type (Torque Type(®), WinSix(®), BioSAFin. S.r.l. - Ancona, Italy), with sandblasted and acid etched surfaces (Micro Rough Surface(®)), but differing from each other for the prosthesis connection system, were examined by scanning electron microscope (SEM) analysis at different magnifications: TTI implant, with a hexagonal internal connection, and TTX implant, with a hexagonal external connection. SEM analysis showed that the Torque Type(®) implant is characterized by a truncated cone shape with tapered tips. The implant body showed a double loop thread and double pitch with blunt tips. For both types of connection, the implant neck was 0.7 mm in height with a 3% taper. This implant design may be able to guarantee osteotomic properties at the time of insertion in a surgical site suitably prepared, a facilitated screwing, thanks to the thread pitch and to the broad and deep draining grooves, thereby ensuring a good primary stability. The different connection design appears defined and precise, in order to ensure a good interface between the fixture and the prosthetic components. Therefore, this design appears to be particularly suitable in cases where a good primary stability is necessary and a precise coupling between endosseous and prosthetic components, as it allows an easy insertion of the fixture even in conditions of reduced bone availability, and in cases of immediately loaded full-arch rehabilitations.

摘要

本研究的目的是评估一种新型种植体设计的宏观和微观外观,特别强调假体连接的类型。对两种相同类型的牙科种植体(Torque Type(®),WinSix(®),BioSAFin. S.r.l. - 意大利安科纳)进行了研究,它们具有喷砂和酸蚀表面(Micro Rough Surface(®)),但假体连接系统不同,通过扫描电子显微镜(SEM)分析在不同放大倍数下进行检查:TTI种植体,具有六边形内部连接,和TTX种植体,具有六边形外部连接。SEM分析表明,Torque Type(®)种植体的特征是截锥形,尖端呈锥形。种植体主体显示出双环螺纹和双螺距,尖端钝圆。对于两种连接类型,种植体颈部高度为0.7 mm,锥度为3%。这种种植体设计在插入适当准备的手术部位时可能能够保证截骨性能,由于螺距以及宽而深的排水槽,拧入更容易,从而确保良好的初始稳定性。不同的连接设计显得明确而精确,以确保固定装置与假体部件之间有良好的界面。因此,这种设计在需要良好初始稳定性以及骨内和假体部件之间精确耦合的情况下似乎特别合适,因为即使在骨量减少的情况下,它也能使固定装置易于插入,并且适用于即刻负重的全牙弓修复情况。

相似文献

本文引用的文献

1
Prosthetic platforms in implant dentistry.口腔种植学中的修复平台
J Craniofac Surg. 2011 Nov;22(6):2327-31. doi: 10.1097/SCS.0b013e318232a706.
7
The effect of implant shape and bone preparation on primary stability.种植体形状和骨预备对初期稳定性的影响。
J Periodontal Implant Sci. 2010 Oct;40(5):239-43. doi: 10.5051/jpis.2010.40.5.239. Epub 2010 Oct 31.
10
The effects of superficial roughness and design on the primary stability of dental implants.表面粗糙度和设计对牙种植体初期稳定性的影响。
Clin Implant Dent Relat Res. 2011 Sep;13(3):215-23. doi: 10.1111/j.1708-8208.2009.00202.x. Epub 2009 Sep 9.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验