Division of Cardiology, Department of Internal Medicine, College of Medicine, Chung-Ang University, Seoul, Korea.
Korean Circ J. 2012 Sep;42(9):618-24. doi: 10.4070/kcj.2012.42.9.618. Epub 2012 Sep 27.
Irregular RR intervals in atrial fibrillation (AF) make beat-to-beat changes in left ventricular (LV) systolic performance. Early diastolic mitral annular velocity (E') is one of the well-established parameters for evaluating LV diastolic function. The relation between RR intervals and E's is unknown. The aim of this study was to observe the influence of continuous changes in RR interval on the parameter for diastolic function in AF.
Echocardiography was performed in 117 patients with AF. E' was adjusted for the effect of pre-preceding RR interval (RR-2) using the logarithmic equation between RR-2 and E'. The logarithmic equation between adjusted E' and preceding RR interval (RR-1) was calculated.
The slope in the relation between RR-1 and E' varied from -2.5 to 2.6. The slope was lower (more likely negative) in patients with higher ratio of early diastolic mitral flow velocity (E) to E' (r=-0.21, p=0.023), ischemic heart disease (IHD, r=0.21, p=0.026), and higher systolic blood pressure (r=-0.19, p=0.046). When patients were divided into these 3 groups on the basis of slope, the lowest slope group (<-0.55, n=39) was associated with higher E'/E (p=0.004) and IHD (p=0.018) compared with the highest slope group (>0.57, n=39). The slope with regards to the relationship between RR-2 and E' also varied from -3.4 to 3.1.
Changes in RR intervals had variable effects on E's according to clinical variables in AF.
心房颤动(AF)中不规则的 RR 间期会导致左心室(LV)收缩性能的逐搏变化。早期舒张二尖瓣环速度(E')是评估 LV 舒张功能的一个既定参数。RR 间期与 E'之间的关系尚不清楚。本研究旨在观察 RR 间期连续变化对 AF 患者舒张功能参数的影响。
对 117 例 AF 患者进行超声心动图检查。使用 RR-2 与 E'之间的对数方程,对 E'进行 RR-2 效应的调整。计算调整后的 E'与前一个 RR 间期(RR-1)之间的对数方程。
RR-1 与 E'之间的关系斜率范围为-2.5 至 2.6。E/E'比值较高(r=-0.21,p=0.023)、患有缺血性心脏病(IHD,r=0.21,p=0.026)和较高的收缩压(r=-0.19,p=0.046)的患者斜率较低(更可能为负值)。根据斜率将患者分为 3 组,斜率最低组(<-0.55,n=39)的 E'/E 比值较高(p=0.004),且更易患有 IHD(p=0.018),与斜率最高组(>0.57,n=39)相比。RR-2 与 E'之间关系的斜率也从-3.4 到 3.1 不等。
在 AF 中,RR 间期的变化根据临床变量对 E'产生不同的影响。