AKK Altonaer Kinderkrankenhaus, Abteilung für Kinderorthopädie, Bleickenallee 38, 22763 Hamburg, Germany.
Arch Orthop Trauma Surg. 2013 Jan;133(1):29-36. doi: 10.1007/s00402-012-1635-z. Epub 2012 Oct 30.
A profound knowledge of physiologic lower limb alignment is essential to understand deformities and to plan surgical correction. The gold standard in radiographic assessment is the long standing radiograph with a forward directed patella. The advantage of computed tomography (CT) is that its cutting-edge image technique can visualize the femur condyles. Study purpose was to determine if the CT-scout view has the potential to replace the standing radiograph.
We compared the geometric data obtained from long standing radiograph and CT-scout views both with patella forward position. Furthermore, we developed a method of positioning the lower extremity stable on the CT table, where the femoral condyles became the new orientation criterion. Finally, we evaluated differences in the data ascertainment between the long standing radiograph with patella facing forward and the CT-scout view with the posterior edge of femoral condyles orientated parallel to the radiographic cassette.
The geometric data of long standing radiograph and CT-scout views are comparable if the leg is in the same rotational position. We developed a CT positioning jig to adjust the femur condyles parallel to the radiographic cassette. In 80 % of the cases, the deviation was 5° or less. These scout views showed statistically significant differences when compared with data from standing radiograph with a forward centered patella.
No evidence was found clearly excluding the possibility of an exclusive use of the CT-scout view for the analysis of the leg geometry. However, advantages of the long standing radiograph became obvious.
深入了解下肢的生理对线对于理解畸形和规划手术矫正至关重要。放射评估的金标准是以前视位髌骨的传统站立位 X 线片。计算机断层扫描(CT)的优势在于其先进的图像技术可以可视化股骨髁。本研究旨在确定 CT 扫描视图是否有可能替代站立位 X 线片。
我们比较了在髌骨前位下获得的长立位 X 线片和 CT 扫描视图的几何数据。此外,我们开发了一种在 CT 台上稳定下肢的方法,使股骨髁成为新的定位标准。最后,我们评估了髌骨前位长立位 X 线片和股骨髁后缘与放射照相盒平行的 CT 扫描视图在数据确定方面的差异。
如果腿部处于相同的旋转位置,长立位 X 线片和 CT 扫描视图的几何数据是可比的。我们开发了一种 CT 定位夹具,以调整股骨髁与放射照相盒平行。在 80%的情况下,偏差为 5°或更小。这些 CT 扫描视图与髌骨前位站立位 X 线片的数据相比存在统计学上的显著差异。
没有明确的证据排除仅使用 CT 扫描视图分析下肢几何形状的可能性。然而,长立位 X 线片的优势变得明显。