Chemisches und Veterinäruntersuchungsamt (CVUA) Karlsruhe, Weißenburger Str. 3, D-76187 Karlsruhe, Germany.
J Chromatogr B Analyt Technol Biomed Life Sci. 2013 May 15;927:223-6. doi: 10.1016/j.jchromb.2012.10.021. Epub 2012 Oct 23.
Substituted imidazoles recently came under scrutiny as they may be indirectly introduced into cola beverages via the use of class IV (E150d) caramel colours and may pose health hazards. A LC/MS/MS method was developed for determining 2- and 4-methylimidazole (2-MI, 4-MI) and 2-acetyl-4-(1,2,3,4)-tetrahydroxybutylimidazole (THI) in beverages and caramel colours. The method is very rapid and easy to conduct as it requires only dilution in eluent for sample preparation. For 4-MI, the recovery was between 94 and 102% for spiked cola samples. The limit of detection was 2μg/L in the measuring solution (corresponding to 40μg/L for cola samples diluted 1:20 during sample preparation). 97 cola samples and 13 caramel colours from Germany and France were analysed. From the 3 analytes, only 4-MI was found in the samples with very varying concentrations (non quantifiable traces to 0.6mg/L in colas and 175-658mg/kg in E150d). The exposure for cola drinkers in worst case scenarios is estimated to be 2-5μg/kg bodyweight/day, which is judged as being only a low risk for public health.
取代的咪唑类物质最近受到了关注,因为它们可能通过使用 IV 类(E150d)焦糖色素而被间接引入可乐饮料中,并可能带来健康风险。本文建立了一种 LC/MS/MS 方法,用于测定饮料和焦糖色素中的 2-和 4-甲基咪唑(2-MI、4-MI)和 2-乙酰基-4-(1,2,3,4)-四羟基丁基咪唑(THI)。该方法非常快速且易于操作,因为仅需用洗脱液稀释即可进行样品制备。对于 4-MI,加标可乐样品的回收率在 94%至 102%之间。测量溶液中的检测限为 2μg/L(相当于可乐样品在样品制备过程中稀释 1:20 时的 40μg/L)。对来自德国和法国的 97 种可乐样品和 13 种焦糖色素进行了分析。在这 3 种分析物中,仅在浓度差异较大的样品中发现了 4-MI(非定量痕量至可乐中的 0.6mg/L 和 E150d 中的 175-658mg/kg)。在最坏情况下,可乐饮用者的暴露量估计为 2-5μg/kg 体重/天,这被认为对公众健康只有低风险。