Department of Otolaryngology Head and Neck Surgery, University of Toronto, Toronto, Ontario, Canada.
Am J Rhinol Allergy. 2012 Sep-Oct;26(5):398-400. doi: 10.2500/ajra.2012.26.3805.
It was previously shown that 50% of irrigation bottles and 40% of irrigation fluids had evidence of bacterial contamination despite cleaning with hot water and soap. Although a novel method of microwave disinfection has recently been proposed to minimize contamination risk, this has not been studied in a real life setting. This study investigates the effectiveness of microwave disinfection for reducing both nasal irrigation bottle and irrigation fluid contamination risk after endoscopic sinus surgery (ESS).
Twenty consecutive patients underwent ESS for chronic rhinosinusitis. Patients were given NeilMed Sinus Rinse bottles (NeilMed Pharmaceuticals, Inc., Santa Rosa CA) to use twice daily, with microwave cleaning instructions preoperatively. Bottles were collected and cultured 1 week postoperatively. Sterile saline (5 mL) was mixed into the irrigation bottle and cultured separately. An additional 10 patients were recruited whereby the bottle was cultured at collection and immediately after microwave disinfection was performed in the clinic.
For the first cohort of the study, 40% of the bottles and 20% of the irrigation samples had positive cultures 1 week postoperatively. Common bacteria included Acinetobacter, coagulase-negative Staphylococcus, and Gram-negative bacilli. For the second cohort of patients, 20% of the irrigation bottles had positive cultures. However, after supervised microwave disinfection, there was a 0% contamination rate.
Despite detailed instructions on microwave disinfection, positive bacterial cultures may still occur after ESS. This risk, however, appears to be significantly reduced when bottles are microwaved under supervision. These findings suggest either a reduced patient compliance to cleaning or a time-dependent recontamination risk after disinfection.
尽管使用热水和肥皂进行了清洗,但之前的研究显示,50%的冲洗瓶和 40%的冲洗液存在细菌污染的证据。虽然最近提出了一种新的微波消毒方法来最大程度地降低污染风险,但尚未在实际环境中进行研究。本研究调查了微波消毒对内窥镜鼻窦手术后(ESS)减少鼻腔冲洗瓶和冲洗液污染风险的有效性。
连续 20 例接受 ESS 治疗慢性鼻-鼻窦炎的患者。患者使用 NeilMed Sinus Rinse 瓶(NeilMed Pharmaceuticals,Inc.,Santa Rosa CA),每天两次,术前给予微波清洁说明。术后 1 周收集并培养瓶子。将无菌生理盐水(5 mL)混入冲洗瓶中并单独培养。另外招募了 10 名患者,即在收集时对瓶子进行培养,并在诊所立即进行微波消毒后进行培养。
在研究的第一组中,术后 1 周 40%的瓶子和 20%的冲洗样本有阳性培养。常见细菌包括不动杆菌、凝固酶阴性葡萄球菌和革兰氏阴性杆菌。对于第二组患者,20%的冲洗瓶有阳性培养。然而,经过监督微波消毒后,污染率为 0%。
尽管有详细的微波消毒说明,但 ESS 后仍可能出现阳性细菌培养。然而,当瓶子在监督下进行微波消毒时,这种风险似乎明显降低。这些发现表明,要么是患者清洁的依从性降低,要么是消毒后存在时间依赖性再污染风险。