Suppr超能文献

评估内镜鼻窦手术后冲洗瓶和液体污染的风险。

Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery.

机构信息

Department of Otolaryngology-Head and Neck Surgery, University of Toronto, St. Michael's Hospital, 30 Bond Street, Toronto, Ontario, Canada.

出版信息

Am J Rhinol Allergy. 2010 May-Jun;24(3):197-9. doi: 10.2500/ajra.2010.24.3481.

Abstract

BACKGROUND

Saline nasal irrigation has become an important aspect of post-operative care following endoscopic sinus surgery. The objective of this study was to identify the risks of contamination of both the nasal irrigation bottle and fluid following endoscopic sinus surgery.

METHODS

This was a prospective study of consecutive patients undergoing endoscopic sinus surgery for chronic sinusitis. All patients were given nasal irrigation bottles with detailed cleaning instructions preoperatively. Nasal irrigation bottles were collected and cultured at 1 and 2 weeks postoperatively. During the same visit, 5-ml of sterile normal saline was mixed into the irrigation bottle and then cultured separately.

RESULTS

A total of 20 patients agreed to participate in the study. At 1 week postoperatively, 50% of the bottles had positive cultures with 40% of the irrigation samples testing positive for bacteria. At two weeks, the contamination in the irrigation bottle and fluid decreased to 26.7% and 20%, respectively. The most common bacteria cultured was Pseudomonas aeruginosa. There were no cases of postoperative infection.

CONCLUSION

Despite detailed cleaning instructions, there is a relatively high risk of bacterial contamination in nasal irrigation bottles and fluid following endoscopic sinus surgery. Although these risks did not translate into higher infection rates postsurgery, it may be important for physicians to emphasize regular cleaning techniques to minimize a potential source of bacterial contaminant exposure.

摘要

背景

盐水鼻腔冲洗已成为鼻内镜鼻窦手术后的重要术后护理措施。本研究旨在确定鼻内镜鼻窦手术后鼻腔冲洗瓶和冲洗液污染的风险。

方法

这是一项对因慢性鼻窦炎接受鼻内镜鼻窦手术的连续患者进行的前瞻性研究。所有患者在术前均给予带有详细清洁说明的鼻腔冲洗瓶。术后 1 周和 2 周采集鼻腔冲洗瓶进行培养。在同一就诊时,将 5ml 无菌生理盐水混入冲洗瓶中并单独进行培养。

结果

共有 20 名患者同意参与研究。术后 1 周时,50%的冲洗瓶有阳性培养结果,40%的冲洗液样本细菌检测阳性。术后 2 周时,冲洗瓶和冲洗液中的污染分别降至 26.7%和 20%。最常见的培养细菌为铜绿假单胞菌。无术后感染病例。

结论

尽管有详细的清洁说明,但鼻内镜鼻窦手术后鼻腔冲洗瓶和冲洗液仍存在较高的细菌污染风险。尽管这些风险并未转化为更高的术后感染率,但医生可能需要强调定期清洁技术,以最大程度地减少细菌污染的潜在来源。