Suppr超能文献

用于测定乳酸阈、固定血乳酸浓度和最大摄氧量的连续递增式跑步机运动方案的可靠性和有效性。

Reliability and validity of a continuous incremental treadmill protocol for the determination of lactate threshold, fixed blood lactate concentrations, and VO2max.

作者信息

Weltman A, Snead D, Stein P, Seip R, Schurrer R, Rutt R, Weltman J

机构信息

Department of Human Services, Memorial Gymnasium, Curry School of Education, University of Virginia, Charlottesville 22903.

出版信息

Int J Sports Med. 1990 Feb;11(1):26-32. doi: 10.1055/s-2007-1024757.

Abstract

Fifteen male runners were tested on two occasions to determine the reliability of a continuous incremental level running treadmill protocol (C), with 3-min stages, for lactate threshold (LT) and fixed blood lactate concentration (FBLC) (2.0 mM, 2.5 mM, 4.0 mM) assessment. Test-retest (T-RT) reliability coefficients for velocity at LT, 2.0 mM, 2.5 mM, and 4.0 mM were r = 0.89, 0.91, 0.95, and 0.95, respectively (velocity ranged from 215.3 m/min at LT to 273.6 m/min at 4.0 mM). Mean differences in T-RT velocity values ranged from 0.7 m/min (at LT) to 6.0 m/min (at 2.5 mM; 252.3 m/min vs 258.3 m/min; NS) and the standard errors of measurement were less than +/- 10.0 m/min. Similar results were observed for VO2, with T-RT r values ranging from r = 0.82 (at LT) to r = 0.88 (at 2.0 mM) (VO2 ranged from 47.2 ml/kg.min-1 at LT to 60.9 ml/kg.min-1 at 4.0 mM; VO2 peak = 65.6 ml/kg.min-1). Mean differences in T-RT VO2 values were less than 1.4 ml/kg.min-1 (NS) and the standard errors of measurement were less than +/- 2.95 ml/kg.min-1. Interinvestigator and intrainvestigator reliability coefficients were high and ranged from r = 0.91 to r = 0.99. Validity of C was assessed in an additional 16 male runners who completed C and a criterion discontinuous (D) protocol (using a series of 10-min stages) for LT and FBLC assessment. Results indicated that C and D resulted in similar VO2 and velocity values at LT and FBLC.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

对15名男性跑步者进行了两次测试,以确定一种连续递增水平跑步跑步机方案(C)的可靠性,该方案有3分钟的阶段,用于评估乳酸阈值(LT)和固定血乳酸浓度(FBLC)(2.0 mM、2.5 mM、4.0 mM)。LT、2.0 mM、2.5 mM和4.0 mM时速度的重测(T-RT)可靠性系数分别为r = 0.89、0.91、0.95和0.95(速度范围从LT时的215.3米/分钟到4.0 mM时的273.6米/分钟)。T-RT速度值的平均差异范围从0.7米/分钟(LT时)到6.0米/分钟(2.5 mM时;252.3米/分钟对258.3米/分钟;无显著性差异),测量标准误差小于±10.0米/分钟。VO2也观察到类似结果,T-RT的r值范围从r = 0.82(LT时)到r = 0.88(2.0 mM时)(VO2范围从LT时的47.2毫升/千克·分钟-1到4.0 mM时的60.9毫升/千克·分钟-1;VO2峰值 = 65.6毫升/千克·分钟-1)。T-RT的VO2值平均差异小于1.4毫升/千克·分钟-1(无显著性差异),测量标准误差小于±2.95毫升/千克·分钟-1。研究者间和研究者内可靠性系数较高,范围从r = 0.91到r = 0.99。在另外16名男性跑步者中评估了方案C的有效性,这些跑步者完成了方案C和一个用于LT和FBLC评估的标准间断(D)方案(使用一系列10分钟阶段)。结果表明,在LT和FBLC时,方案C和方案D产生了相似的VO2和速度值。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验