The [(13)C]-Spirulina platensis gastric emptying breath test (GEBT) with five samples is accurate relative to scintigraphy. This study was primarily designed to further validate this GEBT using a slightly different process for incorporating [(13)C] in Spirulina and to evaluate the utility of additional samples for assessing early gastric emptying.
After a 223 kcal, test meal labeled with (99m) Tc and [(13)C]-S. platensis, scintigraphic images, and five breath samples (45, 90, 120, 180, and 240 min, GEBT5) were collected in 14 controls (Part A). In Part B, nine breath samples were collected at 15, 30, 45, 60, 90, 120, 150, 180, and 240 min (GEBT9) in 30 subjects (15 controls, 15 dyspepsia). Using correlation between [(13)C] breath excretion and scintigraphic emptying, lag time (t(10), time for 10% emptying), emptying at 30 min (GE(30)), and half time (t(50)) were estimated for GEBT5 (Parts A and B) and GEBT9 (Part B).
Half time values for scintigraphy, GEBT5, and GEBT9 were highly concordant. t(10) by GEBT9 (90%CI, 6-15 min) was more strongly correlated [CCC 0.80 (95% CI, 0.63-0.90)] with scintigraphy (90% CI, 5-12 min), than GEBT5 [10-19 min, CCC 0.73 (95% CI, 0.54-0.85)]. The correlation between estimated values (GEBT9) and linearly interpolated values (GEBT5) was closer at 60 [CCC 0.95 (95% CI, 0.91-0.97)] than 30 min [CCC 0.81 (95% CI, 0.71-0.89)].
CONCLUSIONS & INFERENCES: The [(13) C]-S. platensis GEBT can accurately measure GE. While 5- and 9-samples are equally accurate for measuring t(50), GEBT9 provides a more comprehensive assessment of early GE (t(10) and GE(30)).
与闪烁扫描相比,含有五个样本的[(13)C]螺旋藻胃排空呼吸试验(GEBT)更准确。本研究旨在使用稍作改良的方法使螺旋藻掺入[(13)C],进一步验证该 GEBT,并评估增加样本对评估早期胃排空的效用。
14 位对照者(A 部分)在接受 223 千卡测试餐后,接受 99mTc 和 [(13)C]标记的螺旋藻闪烁扫描和五个呼吸样本(45、90、120、180 和 240 分钟,GEBT5)采集。在 B 部分中,30 位受检者(15 位对照者,15 位消化不良患者)接受了 9 个呼吸样本采集(15、30、45、60、90、120、150、180 和 240 分钟,GEBT9)。通过比较[(13)C]呼气排泄与闪烁扫描排空,对 GEBT5(A 部分和 B 部分)和 GEBT9(B 部分)的排空滞后时间(t(10),排空 10%的时间)、30 分钟排空(GE(30))和半衰期(t(50))进行了评估。
闪烁扫描、GEBT5 和 GEBT9 的半衰期值高度一致。GEBT9 的 t(10)(90%CI,6-15 分钟)与闪烁扫描(90%CI,5-12 分钟)相关性更强[CCC 0.80(95%CI,0.63-0.90)],而 GEBT5 的相关性较弱[10-19 分钟,CCC 0.73(95%CI,0.54-0.85)]。GEBT9 的估计值(GEBT9)与线性内插值(GEBT5)的相关性在 60 分钟时更为密切[CCC 0.95(95%CI,0.91-0.97)],而在 30 分钟时则较弱[CCC 0.81(95%CI,0.71-0.89)]。
[(13)C]螺旋藻 GEBT 可准确测量 GE。5 个样本和 9 个样本均可准确测量 t(50),而 GEBT9 可更全面地评估早期 GE(t(10)和 GE(30))。