Pulmonary Division, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
Ann Hematol. 2013 Apr;92(4):517-21. doi: 10.1007/s00277-012-1667-z. Epub 2013 Jan 10.
Alterations in hemoglobin oxygen affinity can be detected by exposing blood to different PO2 and recording oxygen saturation, a method termed tonometry. It is the gold standard to measure the PO2 associated with 50 % oxygen saturation, the index used to quantify oxygen affinity (P50Tono). P50Tono is used in the evaluation of patients with erythrocytosis suspected to have hemoglobin with abnormal oxygen affinity. Since tonometry is labor intensive and not generally available, we investigated whether accurate estimates of P50 could also be obtained by venous blood gas analysis, co-oximetry, and standard equations (P50Ven). In 50 patients referred for evaluation of erythrocytosis, pH, PO2, and oxygen saturation were measured in venous blood to estimate P50Ven; P50Tono was measured for comparison. Agreement among P50Ven and P50Tono was evaluated (Bland-Altman analysis). Mean P50Tono was 25.8 (range 17.4-34.1) mmHg. The mean difference (bias) of P50Tono-P50Ven was 0.5 mmHg; limits of agreement (95 % confidence limits) were -5.2 to +6.1 mmHg. The sensitivity and specificity of P50Ven to identify the 25 patients with P50Tono outside the normal range of 22.9-26.8 mmHg were 5 and 77 %, respectively. We conclude that estimates of P50 based on venous blood gas analysis and standard equations have a low bias compared to tonometry. However, the precision of P50Ven is not sufficiently high to replace P50Tono in the evaluation of individual patients with suspected disturbances of hemoglobin oxygen affinity.
血红蛋白氧亲和力的改变可以通过将血液暴露于不同的 PO2 并记录氧饱和度来检测,这种方法称为张力测定法。它是测量与 50%氧饱和度相关的 PO2 的金标准,用于量化氧亲和力的指标(P50Tono)。P50Tono 用于评估怀疑血红蛋白氧亲和力异常的红细胞增多症患者。由于张力测定法劳动强度大且不普遍,我们研究了是否也可以通过静脉血气分析、比色法和标准方程(P50Ven)准确估计 P50。在 50 名因红细胞增多症就诊的患者中,测量静脉血的 pH、PO2 和氧饱和度以估计 P50Ven;并进行比较测量 P50Tono。评估 P50Ven 和 P50Tono 之间的一致性(Bland-Altman 分析)。P50Tono 的平均值为 25.8(范围 17.4-34.1)mmHg。P50Tono-P50Ven 的平均差异(偏差)为 0.5mmHg;一致性界限(95%置信区间)为-5.2 至+6.1mmHg。P50Ven 识别 25 名 P50Tono 超出 22.9-26.8mmHg 正常范围患者的敏感性和特异性分别为 5%和 77%。我们得出结论,与张力测定法相比,基于静脉血气分析和标准方程的 P50 估计值偏差较低。然而,P50Ven 的精度不足以替代 P50Tono 来评估怀疑血红蛋白氧亲和力异常的个体患者。