Suppr超能文献

使用膨体聚四氟乙烯(戈尔特斯(®))片进行先天性上睑下垂的额肌悬吊术:一年随访

Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex(®)) sheet: one-year follow-up.

作者信息

Nakauchi Kazuaki, Mito Hidenori, Mimura Osamu

机构信息

Hospital of Hyogo College of Medicine, Hyogo.

出版信息

Clin Ophthalmol. 2013;7:131-6. doi: 10.2147/OPTH.S39057. Epub 2013 Jan 16.

Abstract

BACKGROUND

The frontalis suspension technique is the surgical method of choice in patients with ptosis and a levator function of 4 mm or less. Several types of materials have been used, including Gore-Tex(®), which has been used successfully as a frontalis sling material since 1986. Recently, a Gore-Tex sheet (wider than a sling or strip) suspension was reported. This paper reports the results of 27 eyes from 20 patients with congenital ptosis treated using the frontalis suspension technique with the newly developed Gore-Tex Most Versatile Patch (MVP) sheet.

METHODS

All patients underwent surgery between April 2007 and September 2011 and were followed up for at least one year. The average follow-up duration was 18 months, with a range of 12-36 months. The average patient age was 45 (5-85) years, and the group included 11 males and nine females. Thirteen cases demonstrated ptosis in one eye, and seven cases involved both eyes. The patients were divided by age into a younger group and an older group. All ptosis procedures were performed using the Gore-Tex MVP sheet. The implant was normally 7 mm wide for adults and 5 mm wide for children. The implantation method was the same as that used for the sheet shape fascia.

RESULTS

In all patients, satisfactory functional results were observed at the 6-month follow-up examination. Eyelid opening heights were also obtained. The average marginal reflex distance (MRD) was -0.5 mm preoperatively, which improved to +1.9 mm after surgery. After one year, average MRD was +1.6 mm. MRD attenuation was more frequent in the younger group. There were no cases requiring redo surgery and only one case of exposure.

摘要

背景

额肌悬吊术是上睑下垂且提上睑肌功能在4毫米及以下患者的首选手术方法。已使用多种材料,包括自1986年以来成功用作额肌吊带材料的戈尔特斯(Gore-Tex®)。最近,有报道采用戈尔特斯片材(比吊带或条带更宽)进行悬吊。本文报告了使用新开发的戈尔特斯多功能补片(MVP)片材通过额肌悬吊术治疗的20例先天性上睑下垂患者的27只眼的结果。

方法

所有患者于2007年4月至2011年9月接受手术,并至少随访一年。平均随访时间为18个月,范围为12至36个月。患者平均年龄为45(5 - 85)岁,其中男性11例,女性9例。13例为单眼上睑下垂,7例为双眼上睑下垂。患者按年龄分为年轻组和老年组。所有上睑下垂手术均使用戈尔特斯MVP片材进行。成人植入物通常宽7毫米,儿童宽5毫米。植入方法与片状筋膜相同。

结果

所有患者在6个月的随访检查中均观察到满意的功能结果。还获得了眼睑开口高度。术前平均边缘反射距离(MRD)为 -0.5毫米,术后改善至 +1.9毫米。一年后,平均MRD为 +1.6毫米。年轻组中MRD衰减更频繁。没有需要再次手术的病例,仅有1例暴露病例。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d76d/3549676/7afd0d51f6ca/opth-7-131f1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验