College of Podiatric Medicine and Surgery, Des Moines University, Des Moines, IA, USA.
J Foot Ankle Res. 2013 Mar 3;6(1):7. doi: 10.1186/1757-1146-6-7.
The Lisfranc ligament plays an integral role in providing stability to the midfoot. Variable clinical presentations and radiographic findings make injuries to the Lisfranc ligament notoriously difficult to diagnose. Currently, radiographic evaluation is the mainstay in imaging such injuries; however, ultrasound has been suggested as a viable alternative. The objective of this study was to evaluate the intra-rater and inter-rater reliability in the measurement of the length of the dorsal Lisfranc ligament using ultrasound imaging in healthy, asymptomatic subjects.
The dorsal Lisfranc ligaments of fifty asymptomatic subjects (n = 100 feet) were imaged using a Siemens SONOLINE Antares Ultrasound Imaging System© under low, medium, and high stress loads at 0° and 15° abducted foot positions. The lengths of the ligaments were measured, and Interclass correlation coefficients were used to calculate within-session intra-rater reliability (n = 100 feet) as well as between-session intra-rater reliability (n = 40 feet) and between-session inter-rater reliability (n = 40 feet).
The within-session intra-rater reliability results for dorsal Lisfranc ligament length had an average ICC of 0.889 (min 0.873 max 0.913). The average ICC for between-session intra-rater reliability was 0.747 (min 0.607 max 0.811). The average ICC for between-session inter-rater reliability was 0.685 (min 0.638 max 0.776).
The measurement of the dorsal Lisfranc ligament length using ultrasound imaging shows substantial to almost perfect reliability when evaluating asymptomatic subjects. This imaging modality methodology shows promise and lays the foundation for further work in technique development towards the diagnostic identification of pathology within the Lisfranc ligament complex.
Lisfranc 韧带在中足稳定性中起着不可或缺的作用。由于 Lisfranc 韧带损伤的临床表现和影像学表现变化多样,因此很难诊断。目前,影像学评估是此类损伤的主要手段;然而,超声已被认为是一种可行的替代方法。本研究的目的是评估在健康、无症状受试者中使用超声成像测量背侧 Lisfranc 韧带长度的内部和外部观察者之间的可靠性。
使用 Siemens SONOLINE Antares 超声成像系统©在 0°和 15°外展足部位置下对 50 名无症状受试者(n=100 只脚)的背侧 Lisfranc 韧带进行成像。测量韧带的长度,并使用组内相关系数计算测量结果的内部观察者之间的日内信度(n=100 只脚)、日内内部观察者之间的信度(n=40 只脚)和日内外部观察者之间的信度(n=40 只脚)。
背侧 Lisfranc 韧带长度的日内内部观察者信度结果的平均 ICC 为 0.889(最小 0.873,最大 0.913)。日内内部观察者之间信度的平均 ICC 为 0.747(最小 0.607,最大 0.811)。日内外部观察者之间信度的平均 ICC 为 0.685(最小 0.638,最大 0.776)。
在评估无症状受试者时,使用超声成像测量背侧 Lisfranc 韧带长度具有显著的可靠性,接近完美。这种成像方法具有很大的潜力,为进一步发展技术以诊断 Lisfranc 韧带复合体中的病变奠定了基础。