Southern Health, Allied Health Clinical Research Unit, Kingston Centre, Cheltenham, Victoria, Australia.
J Sci Med Sport. 2013 Sep;16(5):392-5. doi: 10.1016/j.jsams.2013.02.001. Epub 2013 Mar 13.
The weight bearing lunge test is increasing being used by health care clinicians who treat lower limb and foot pathology. This measure is commonly established accurately and reliably with the use of expensive equipment. This study aims to compare the digital inclinometer with a free app, TiltMeter on an Apple iPhone.
This was an intra-rater and inter-rater reliability study. Two raters (novice and experienced) conducted the measurements in both a bent knee and straight leg position to determine the intra-rater and inter-rater reliability. Concurrent validity was also established.
Allied health practitioners were recruited as participants from the workplace. A preconditioning stretch was conducted and the ankle range of motion was established with the weight bearing lunge test position with firstly the leg straight and secondly with the knee bent. The measurement device and each participant were randomised during measurement.
The intra-rater reliability and inter-rater reliability for the devices and in both positions were all over ICC 0.8 except for one intra-rater measure (Digital inclinometer, novice, ICC 0.65). The inter-rater reliability between the digital inclinometer and the tilmeter was near perfect, ICC 0.96 (CI: 0.898-0.983); Concurrent validity ICC between the two devices was 0.83 (CI: -0.740 to 0.445).
The use of the Tiltmeter app on the iPhone is a reliable and inexpensive tool to measure the available ankle range of motion. Health practitioners should use caution in applying these findings to other smart phone equipment if surface areas are not comparable.
承重单腿下蹲测试越来越多地被治疗下肢和足部疾病的医疗保健临床医生使用。这种测量方法通常需要使用昂贵的设备才能准确可靠地进行。本研究旨在比较数字倾角仪和免费的苹果 iPhone 应用程序 TiltMeter。
这是一项内部和外部观察者可靠性研究。两名观察者(新手和有经验者)在屈膝和直腿两种姿势下进行测量,以确定内部和外部观察者的可靠性。同时还建立了同时效度。
从工作场所招募了辅助医疗从业者作为参与者。进行了预条件拉伸,并且在承重单腿下蹲测试位置下确定了踝关节的活动范围,首先是腿部伸直,其次是膝盖弯曲。在测量过程中,测量设备和每个参与者都是随机的。
在设备和两种姿势下,除了一个内部观察者测量值(数字倾角仪,新手,ICC 0.65)外,内部和外部观察者的可靠性均超过 ICC 0.8。数字倾角仪和 TiltMeter 之间的观察者间可靠性接近完美,ICC 0.96(CI:0.898-0.983);两种设备之间的同时效度 ICC 为 0.83(CI:-0.740 至 0.445)。
使用 iPhone 上的 TiltMeter 应用程序是一种可靠且廉价的工具,可测量可获得的踝关节活动范围。如果表面区域不可比,健康从业者在将这些发现应用于其他智能手机设备时应谨慎。