An in vitro study testing the reliability of chemical determinations on blood samples withdrawn through an umbilical catheter is described. Blood samples were withdrawn through three different sizes of umbilical catheters containing a solution of dextrose, sodium bicarbonate, and potassium. Using either a 5 French or a 3 1/2 French catheter, accurate results were obtained for pH, sodium, potassium, and glucose when measurements were made after an initial 4-ml blood sample was discarded. With an 8 French catheter, accurate results were obtained for pH, sodium, and potassium but plasma glucose determinations remained inaccurate after 6 ml of blood was discarded.

摘要

本文描述了一项体外研究,该研究测试了通过脐静脉导管采集的血样进行化学检测的可靠性。血样通过三种不同尺寸的脐静脉导管采集,这些导管中含有葡萄糖、碳酸氢钠和钾的溶液。使用5法国或3.5法国的导管时,在丢弃最初4毫升血样后进行测量,pH值、钠、钾和葡萄糖的检测结果准确。使用8法国的导管时,pH值、钠和钾的检测结果准确,但在丢弃6毫升血样后,血浆葡萄糖的检测结果仍然不准确。