Abstract

To reduce radiation exposure and cost, visceral adipose tissue (VAT) measurement on X-ray computed tomography (CT) has been limited to a single slice. Recently, the US Food and Drug Administration has approved a dual-energy X-ray absorptiometry (DXA) application validated against CT to measure VAT volume. The purpose of this study was to develop an algorithm to compute single-slice area values on DXA at 2 common landmarks, L2/3 and L4/5, from an automated volumetrically derived measurement of VAT. Volumetric CT and total body DXA were measured in 55 males (age: 21-77 yr; body mass index [BMI]: 21.1-37.9) and 60 females (age: 21-85 yr; BMI: 20.0-39.7). Equations were developed by applying the relationship of CT single-slice area and volume measurements of VAT to the DXA VAT volume measure as well as validating these against the CT single-slice measurements. Correlation coefficients between DXA estimate of single-slice area and CT were 0.94 for L2/3 and 0.96 for L4/5. The mean difference between DXA estimate of single-slice area and CT was 5 cm(2) at L2/3 and 3.8 cm(2) at L4/5. Bland-Altman analysis showed a fairly constant difference across the single-slice range in this study, and the 95% limits of agreement for the 2 methods were -44.6 to +54.6 cm(2) for L2/3 and -47.3 to +54.9 cm(2) for L4/5. In conclusion, a volumetric measurement of VAT by DXA can be used to estimate single-slice measurements at the L2/3 and the L4/5 landmarks.

摘要

为了降低辐射暴露和成本,X 射线计算机断层扫描(CT)上的内脏脂肪组织(VAT)测量仅限于单一切片。最近,美国食品和药物管理局已批准了一种双能 X 射线吸收法(DXA)应用程序,该程序通过 CT 验证来测量 VAT 体积。本研究的目的是开发一种算法,以便根据自动容积测量值,在 L2/3 和 L4/5 两个常见标记处,计算 DXA 上的单切片面积值。在 55 名男性(年龄:21-77 岁;体重指数[BMI]:21.1-37.9)和 60 名女性(年龄:21-85 岁;BMI:20.0-39.7)中测量了容积 CT 和全身 DXA。通过将 VAT 的 CT 单切片面积和体积测量值与 DXA VAT 体积测量值相关联,开发了方程式,并通过 CT 单切片测量对其进行了验证。DXA 估计的单切片面积与 CT 之间的相关系数分别为 L2/3 处的 0.94 和 L4/5 处的 0.96。在 L2/3 处,DXA 估计的单切片面积与 CT 之间的平均差异为 5cm²,在 L4/5 处为 3.8cm²。Bland-Altman 分析显示,在本研究中单切片范围内的差异相当恒定,两种方法的 95%一致性界限分别为 L2/3 处的-44.6 至+54.6cm²和 L4/5 处的-47.3 至+54.9cm²。总之,DXA 对 VAT 的容积测量可用于估计 L2/3 和 L4/5 标记处的单切片测量值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验