BACKGROUND

Quetiapine is an atypical antipsychotic agent for the treatment of schizophrenia, acute mania, and acute bipolar depression. The antidepressive response is considered to be mediated by the metabolite norquetiapine (N-desalkylquetiapine), and the aim of this study was to develop an LC-MS/MS method to measure concentrations of these compounds in human plasma.

METHODS

Following one step liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a Sunfire C18 column (50mm×2.1mm, 5μm). The retention times were 2.12, 2.24, 2.12 and 2.19min for quetiapine, norquetiapine and their respective stable labeled internal standards, respectively. Cycle time was 4min. Selected reaction monitoring (SRM) in positive ion mode was used for quantitation.

RESULTS

The present method exhibited a linear dynamic range of 0.5-500ng/ml for quetiapine and 0.6-600ng/ml for norquetiapine. The applicable range was extended by dilution up to 5-fold with blank matrix. The accuracy and precision for quetiapine were <103.0% and 8.8%, for norquetiapine were <108.8% and 11.1%, respectively.

CONCLUSIONS

A rapid, sensitive, and robust LC-MS/MS method for quantifying quetiapine and its metabolite norquetiapine levels in human plasma was validated and successfully applied to samples from schizophrenic patients in clinical pharmacokinetics studies.

摘要

背景

喹硫平是一种用于治疗精神分裂症、急性躁狂症和急性双相抑郁症的非典型抗精神病药物。抗抑郁反应被认为是由代谢物去甲喹硫平(N-去甲喹硫平)介导的,本研究旨在开发一种 LC-MS/MS 方法来测量人血浆中这些化合物的浓度。

方法

采用一步液-液萃取法,在 Sunfire C18 柱(50mm×2.1mm,5μm)上采用等度流动相分离分析物。喹硫平、去甲喹硫平和各自稳定标记的内标物的保留时间分别为 2.12、2.24、2.12 和 2.19min。循环时间为 4min。采用正离子模式下的选择反应监测(SRM)进行定量。

结果

本方法显示喹硫平的线性动态范围为 0.5-500ng/ml,去甲喹硫平的线性动态范围为 0.6-600ng/ml。通过用空白基质稀释多达 5 倍,可以扩展适用范围。喹硫平的准确度和精密度均<103.0%和 8.8%,去甲喹硫平的准确度和精密度均<108.8%和 11.1%。

结论

本研究建立了一种快速、灵敏、可靠的 LC-MS/MS 方法,用于定量分析人血浆中的喹硫平和其代谢物去甲喹硫平水平,并成功应用于精神分裂症患者的临床药代动力学研究中。