Haluck R S, Richenbacher W E, Myers J L, Miller C A, Wise R K, Waldhausen J A
Department of Surgery, College of Medicine, Pennsylvania State University, Hershey 17033.
J Surg Res. 1990 Jun;48(6):611-4. doi: 10.1016/0022-4804(90)90240-3.
The repair of complex coarctation of the aorta often requires an aortic patch. Prosthetic patches lack growth potential and are associated with an increased incidence of aneurysm formation opposite the patch. We compared buffered glutaraldehyde-fixed patches, used in six animals (group 1), and untreated autologous pericardial aortic patches, used in five animals (group 2). Weanling pigs underwent pericardial patch replacement of a 1 X 2-cm diamond-shaped segment of the lateral wall of the descending thoracic aorta at the level of the aortic isthmus. Six months following patch aortoplasty, the animals were killed and the in situ patch dimensions were measured and compared to the measurements obtained at implantation. The increases in length, recorded as mean percentage change +/- SEM, were 34.7 +/- 3.7% for group 1 and 102.8 +/- 20.3% for group 2 animals; the increases in width were 91.4 +/- 31.7% for group 1 and 192.4 +/- 31.4% for group 2. The percentage changes for both length and width were significantly different between groups (P less than 0.05). Pull strength testing of standard-size patch samples demonstrated no significant difference in tensile breaking load between groups: group 1 = 959 +/- 277 g, group 2 = 795 +/- 86 g. Thoracic aortography revealed no evidence of stenosis or aneurysmal dilation in either group. Autologous pericardium is resilient, strong, and readily available and has expansile potential that makes it an ideal aortic patch material. We conclude that glutaraldehyde fixation does not provide additional strength and limits graft expansile potential when compared to untreated pericardium.
主动脉复杂缩窄的修复通常需要使用主动脉补片。人工补片缺乏生长潜力,且与补片对侧动脉瘤形成的发生率增加有关。我们比较了六只动物使用的经缓冲戊二醛固定的补片(第1组)和五只动物使用的未处理自体心包主动脉补片(第2组)。断奶仔猪在主动脉峡部水平对降主动脉侧壁1×2厘米菱形节段进行心包补片置换。补片主动脉成形术后六个月,处死动物并测量原位补片尺寸,并与植入时获得的测量值进行比较。长度增加量记录为平均百分比变化±标准误,第1组动物为34.7±3.7%,第2组动物为102.8±20.3%;宽度增加量第1组为91.4±31.7%,第2组为192.4±31.4%。两组之间长度和宽度的百分比变化均有显著差异(P<0.05)。标准尺寸补片样本的拉伸强度测试表明,两组之间的拉伸断裂载荷无显著差异:第1组=959±277克,第2组=795±86克。胸部主动脉造影显示两组均无狭窄或动脉瘤样扩张的证据。自体心包具有弹性、坚固且易于获取,并且具有扩张潜力,使其成为理想的主动脉补片材料。我们得出结论,与未处理的心包相比,戊二醛固定并不能提供额外的强度,且会限制移植物的扩张潜力。