Division of Cardiology, Korea University Medical Center, 126-1 Anam-Dong 5Ga, Seongbuk-Gu, Seoul, 136-705, South Korea.
Int J Cardiovasc Imaging. 2013 Oct;29(7):1423-32. doi: 10.1007/s10554-013-0230-x. Epub 2013 Apr 28.
This study evaluated the feasibility and accuracy of three-dimensional rotational angiography (3DRA) to determine the anatomy of the left atrium (LA) and pulmonary veins (PVs) compared with cardiac computed tomography (CCT) and trans-thoracic echocardiography (TTE). One hundred two patients (56.1 ± 9.9 years, 86 males) with an indication for atrial fibrillation ablation were prospectively enrolled. Intra-procedural 3DRA was performed with power injected contrast medium (20 cc/s for 4 s, 240°) in the LA. 3DRA images of the LA and PVs were assessed qualitatively and then compared quantitatively. LA volume measured by 3DRA, CCT and TTE were compared. The majority of 3DRA acquisitions were optimal in delineating the right-side LA-PV (95 % for right superior PV and 96 % for right inferior PV) and left inferior PV anatomy (91 %), whereas it was optimal in only 63 % of left superior PV and 73 % of the LA appendage. The circumferences of PV ostia identified by 3DRA and CCT were correlated in four PVs (r = 0.57 for right superior PV, r = 0.67 for right inferior PV, r = 0.60 for left superior PV, and r = 0.52 for left inferior PV, p < 0.001). The mean LA volume measured by 3DRA (120 ± 32 mL) was greater than that found by CCT (109 ± 35 mL) or TTE (64 ± 23 mL), but the 3DRA LA volume measurements correlated well with those of CCT (r = 0.83, p < 0.001) and TTE (r = 0.69, p < 0.001). Intra-procedural 3DRA provided anatomical accuracy of LA and PVs comparable to those of CCT. However, optimal delineation of the left superior PV and LA appendage was limited. The LA volume determined by 3DRA was well correlated with those of CCT and TTE, despite different absolute values of each.
这项研究评估了三维旋转血管造影术(3DRA)在确定左心房(LA)和肺静脉(PV)解剖结构方面的可行性和准确性,与心脏计算机断层扫描(CCT)和经胸超声心动图(TTE)进行了比较。102 名有房颤消融适应证的患者(56.1±9.9 岁,86 名男性)前瞻性入组。在 LA 中以 20 cc/s 的速度注入造影剂(4 s,240°)进行术中 3DRA。对 LA 和 PV 的 3DRA 图像进行定性评估,然后进行定量比较。比较了由 3DRA、CCT 和 TTE 测量的 LA 容积。大多数 3DRA 采集能够很好地描绘右侧 LA-PV(右上 PV 为 95%,右下 PV 为 96%)和左下 PV 解剖结构(91%),而左上 PV 只有 63%和左心耳只有 73%的采集结果为最佳。3DRA 和 CCT 识别的 PV 口周长在 4 个 PV 中具有相关性(右上 PV 为 r = 0.57,右下 PV 为 r = 0.67,左上 PV 为 r = 0.60,左下 PV 为 r = 0.52,p<0.001)。3DRA 测量的 LA 容积(120±32mL)大于 CCT(109±35mL)或 TTE(64±23mL),但 3DRA LA 容积测量与 CCT(r = 0.83,p<0.001)和 TTE(r = 0.69,p<0.001)具有良好的相关性。术中 3DRA 提供了与 CCT 相当的 LA 和 PV 解剖结构准确性。然而,左上 PV 和左心耳的最佳描绘受到限制。3DRA 确定的 LA 容积与 CCT 和 TTE 的容积密切相关,尽管每个的绝对值不同。