Comparison of hyperpolarized (3)He and (129)Xe MRI for the measurement of absolute ventilated lung volume in rats.

作者信息

Fox Matthew S, Ouriadov Alexei, Santyr Giles E

机构信息

Department of Physics and Astronomy, Western University, London, Canada; Imaging Research Laboratories, Robarts Research Institute, Western University, London, Canada.

出版信息

Magn Reson Med. 2014 Mar;71(3):1130-6. doi: 10.1002/mrm.24746.

Abstract

PURPOSE

MRI using hyperpolarized noble gases, (3)He and (129)Xe, provides noninvasive assessments of lung structure and function. Previous work demonstrated that absolute ventilated lung volumes (aVLV) measured in rats using hyperpolarized (3)He agree well with micro-CT.

METHODS

In this work, aVLV measurements were performed in rats using hyperpolarized (129)Xe MRI and compared with hyperpolarized (3)He measurements of aVLV under matched ventilation conditions. Whole-lung compliance was also determined. Partial volume, apparent diffusion coefficient, and effective transverse relaxation time corrections were applied during postprocessing to reduce bias between methods.

RESULTS

Mean apparent diffusion coefficient of the trachea was 0.83 ± 0.09 cm(2)/s and 0.067 ± 0.011 cm(2)/s for (3)He and (129)Xe, respectively. Mean apparent diffusion coefficient of parenchyma was 0.21 ± 0.07 cm(2)/s and 0.027 ± 0.008 cm(2)/s for (3)He and (129)Xe, respectively. Mean transverse relaxation time values were 1.57 ± 0.25 ms and 2.80 ± 0.25 ms for (3)He and (129)Xe, respectively, in a model trachea and 3.18 ± 1.00 ms and 4.88 ± 0.60 ms for (3)He and (129)Xe, respectively, for lung parenchyma. Mean aVLV values were 7.07 ± 0.67 mL and 6.99 ± 1.00 mL at 14 cmH2O and 4.88 ± 0.71 mL and 5.36 ± 0.76 mL at 10 cmH2O obtained with (3)He and (129)Xe, respectively, demonstrating good agreement between (129)Xe and (3)He.

CONCLUSIONS

(129)Xe offers an important alternative to (3)He for hyperpolarized gas MRI of aVLV in rats.

摘要

目的

使用超极化惰性气体(3)He和(129)Xe进行的MRI可对肺结构和功能进行无创评估。先前的研究表明,使用超极化(3)He在大鼠中测量的绝对通气肺容积(aVLV)与微型CT测量结果高度吻合。

方法

在本研究中,使用超极化(129)Xe MRI对大鼠进行aVLV测量,并与在匹配通气条件下超极化(3)He测量的aVLV进行比较。还测定了全肺顺应性。在处理过程中应用了部分容积、表观扩散系数和有效横向弛豫时间校正,以减少方法之间的偏差。

结果

气管的平均表观扩散系数对于(3)He和(129)Xe分别为0.83±0.09 cm²/s和0.067±0.011 cm²/s。实质的平均表观扩散系数对于(3)He和(129)Xe分别为0.