Suppr超能文献

瑞典版矫形器与假肢用户调查问卷的重测信度

Test-retest reliability of the Swedish version of the Orthotics and Prosthetics Users' Survey.

作者信息

Jarl Gustav, Holmefur Marie, Hermansson Liselotte M N

机构信息

1Centre for Rehabilitation Research, Örebro County Council, Örebro, Sweden.

出版信息

Prosthet Orthot Int. 2014 Feb;38(1):21-6. doi: 10.1177/0309364613485113. Epub 2013 May 7.

Abstract

BACKGROUND

The Orthotics and Prosthetics Users' Survey consists of five modules to assess outcomes of orthotic and prosthetic interventions: lower extremity functional status, upper extremity functional status, client satisfaction with device, client satisfaction with services and health-related quality of life.

OBJECTIVES

To investigate the test-retest reliability and calculate the smallest detectable difference for all modules of the Swedish Orthotics and Prosthetics Users' Survey.

STUDY DESIGN

Test-retest reliability study design.

METHODS

A total of 69 patients at a Department of Prosthetics and Orthotics completed Orthotics and Prosthetics Users' Survey on two occasions separated by a 2-week interval, giving 18 answers on lower extremity functional status, 41 on upper extremity functional status, 53 on client satisfaction with device, 12 on client satisfaction with services and 67 answers on health-related quality of life. Raw scores were converted into Orthotics and Prosthetics Users' Survey units on a 0-100 scale. Intra-class correlation coefficients, Bland-Altman plots, common person linking plots and t-tests of person mean measures were used to investigate the reliability. The 95% confidence level smallest detectable differences were calculated.

RESULTS

The intra-class correlation coefficients ranged from 0.77 to 0.96 for the modules, and no systematic differences were detected between the response occasions. The smallest detectable differences ranged from 7.4 to 16.6 units.

CONCLUSIONS

The test-retest reliability was satisfactory for all Orthotics and Prosthetics Users' Survey modules. The smallest detectable difference was large on all modules except the health-related quality of life module.

CLINICAL RELEVANCE

The Orthotics and Prosthetics Users' Survey modules are reliable and, thus, can be recommended for repeated measurements of patients over time. Relatively large changes are needed to achieve statistical significance when assessing individual patients.

摘要

背景

矫形器与假肢使用者调查由五个模块组成,用于评估矫形器和假肢干预的效果:下肢功能状态、上肢功能状态、使用者对器械的满意度、使用者对服务的满意度以及与健康相关的生活质量。

目的

调查瑞典矫形器与假肢使用者调查所有模块的重测信度,并计算最小可检测差异。

研究设计

重测信度研究设计。

方法

一家假肢与矫形器科的69名患者分两次完成了矫形器与假肢使用者调查,两次调查间隔2周,共获得18份关于下肢功能状态的回答、41份关于上肢功能状态的回答、53份关于使用者对器械满意度的回答、12份关于使用者对服务满意度的回答以及67份关于与健康相关生活质量的回答。原始分数被转换为0至100分制的矫形器与假肢使用者调查单位。使用组内相关系数、布兰德-奥特曼图、普通人连接图以及个体均值测量的t检验来调查信度。计算了95%置信水平下的最小可检测差异。

结果

各模块的组内相关系数在0.77至0.96之间,两次回答之间未检测到系统差异。最小可检测差异在7.4至16.6个单位之间。

结论

矫形器与假肢使用者调查所有模块的重测信度令人满意。除与健康相关的生活质量模块外,所有模块的最小可检测差异都较大。

临床意义

矫形器与假肢使用者调查模块是可靠的,因此可推荐用于对患者进行长期的重复测量。在评估个体患者时,需要相对较大的变化才能达到统计学显著性。