Suppr超能文献

两种基于载体的根管充填剂适应性和封闭能力的体外比较研究。

An in vitro comparative study of the adaptation and sealing ability of two carrier-based root canal obturators.

作者信息

Alkahtani Ahmed, Al-Subait Sara, Anil Sukumaran

机构信息

Department of Restorative Dental Sciences, College of Dentistry, King Saud University, P.O. Box 300353, Riyadh 11372, Saudi Arabia.

出版信息

ScientificWorldJournal. 2013 May 9;2013:532023. doi: 10.1155/2013/532023. Print 2013.

Abstract

The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

摘要

本研究旨在评估RealSeal 1的封闭能力和适应性,并将其与Thermafil进行比较。选取65颗单根离体牙进行根管治疗。根管分别用RealSeal 1或Thermafil进行充填。建立了使用粪肠球菌的双腔细菌渗漏模型来评估封闭能力。对样本进行为期60天的每日监测。细菌渗漏试验后,将样本包埋在树脂中,并在距根尖孔2毫米和4毫米处水平切片。在扫描电子显微镜下检查标本并进行数码拍照。使用AutoCAD软件测量根管壁表面与充填材料之间的间隙。对细菌渗漏结果采用非参数Kaplan-Meier生存分析进行统计学分析,对RealSeal 1和Thermafil在2毫米和4毫米处的间隙均值采用t检验进行比较。RealSeal 1和Thermafil在随时间的渗漏方面没有显著差异。在2毫米和4毫米处,RealSeal 1的间隙明显多于Thermafil。从观察结果可以得出结论,RealSeal 1和Thermafil在适应性和封闭能力方面具有相当的性能。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验