We describe a general Biacore method for measuring equilibrium binding affinities and stoichiometries for interactions between unmodified proteins and their unmodified ligands free in solution. Mixtures of protein and ligand are preequilibrated at different ratios in solution and then analyzed by Biacore using a sensor chip surface that detects only unbound analyte. Performing the Biacore analysis under mass transport limited conditions allows the concentration of unbound analyte to be determined from the initial velocity of binding. Plots of initial velocity versus the concentration of the varied binding partner are fitted to a quadratic binding equation to give the affinity and stoichiometry of binding. We demonstrate the method using soluble Her2 extracellular domain binding to monovalent, bivalent, and trivalent forms of an anti-Her2 antibody. The affinity we measured agrees with that obtained from conventional Biacore kinetic analysis, and the stoichiometries for the resulting 1:1, 1:2, and 1:3 complexes were confirmed by gel filtration with in-line light scattering. The method is applicable over an affinity range of approximately 100 pM to 1 μM and is particularly useful when there is concern that covalently modifying one or the other binding partner might affect its binding properties or where multivalency might otherwise complicate a quantitative analysis of binding.

摘要

我们描述了一种通用的 Biacore 方法,用于测量溶液中未修饰的蛋白质与其未修饰配体之间相互作用的平衡结合亲和力和计量比。将蛋白质和配体的混合物在溶液中以不同的比例预先平衡,然后使用仅检测未结合分析物的传感器芯片表面通过 Biacore 进行分析。在质量传递受限条件下进行 Biacore 分析,可以从结合的初始速度确定未结合分析物的浓度。将初始速度与变化的结合伙伴的浓度的关系绘制为二次结合方程,以给出结合的亲和力和计量比。我们使用可溶性 Her2 细胞外结构域与单价、二价和三价形式的抗 Her2 抗体来演示该方法。我们测量的亲和力与从传统 Biacore 动力学分析获得的亲和力一致,并且通过在线光散射的凝胶过滤确认了所得 1:1、1:2 和 1:3 复合物的计量比。该方法适用于约 100 pM 至 1 μM 的亲和力范围,当有担心修饰一个或另一个结合伙伴可能会影响其结合特性,或者多价性可能会使结合的定量分析复杂化时,该方法特别有用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0767/8627677/5d0e64a5f59b/nihms611071f1.jpg

相似文献

5
Measuring Protein-Protein Interactions Using Biacore.使用Biacore测量蛋白质-蛋白质相互作用
Methods Mol Biol. 2017;1485:339-354. doi: 10.1007/978-1-4939-6412-3_17.

引用本文的文献

本文引用的文献

4
Ligand binding assays at equilibrium: validation and interpretation.平衡态配体结合分析:验证与解读。
Br J Pharmacol. 2010 Nov;161(6):1219-37. doi: 10.1111/j.1476-5381.2009.00604.x.
6
Cooperativity and biological complexity.协同性与生物复杂性。
Nat Chem Biol. 2008 Aug;4(8):435-9. doi: 10.1038/nchembio0808-435.
10
Binding parameters of antibodies: pseudo-affinity and other misconceptions.抗体的结合参数:假亲和力及其他误解
Cancer Immunol Immunother. 2005 Jun;54(6):513-6. doi: 10.1007/s00262-004-0644-3. Epub 2004 Dec 31.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验