Suppr超能文献

超声测量年轻无症状人群和腰痛患者腰多裂肌深层和浅层的组内测量可靠性

Inter-session reliability of the measurement of the deep and superficial layer of lumbar multifidus in young asymptomatic people and patients with low back pain using ultrasonography.

作者信息

Liu I-Shan, Chai Huei-Ming, Yang Jing-Lan, Wang Shwu-Fen

机构信息

Division of Physical Therapy, Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan.

出版信息

Man Ther. 2013 Dec;18(6):481-6. doi: 10.1016/j.math.2013.04.006. Epub 2013 May 28.

Abstract

STUDY DESIGN

Reliability study.

OBJECTIVE

To investigate the inter-session reliability of measuring the thickness of deep (dMF) and superficial layer of lumbar multifidus (sMF) using ultrasonography for participants with and without low back pain (LBP).

BACKGROUND

The lumbar multifidus is an important muscle in maintaining spinal stability. The dMF is considered important in maintaining tonic contraction and joint stability. Motor control impairment is also discovered in patients with LBP. However, no study to date has investigated the method of observing both the sMF and dMF through ultrasound imaging (USI).

METHODS

Twenty subjects aged 18-35 years old with LBP (N=10) and without LBP (N=10) were recruited. Every subject extended the upper trunk in prone lying with maximal isometric contraction. Simultaneously, the examiner measured the thickness of the dMF and the sMF using ultrasonography after ensuring the muscle belly was located. The participants performed three trials of isometric trunk extension in each session, with 30 min between each session. The reliability of measuring the change of thickness is represented by the intra-class correlation coefficient (ICC).

RESULTS

Through averaging three trials of measurement, the reliability of measuring the thickness of the dMF or the sMF in static or in the contracted condition, and the change of the thickness during contraction, is reliable (ICC=0.84-1.00).

CONCLUSIONS

The intra-rater inter-session reliability of measurement of the dMF and the sMF with USI has been established. This method could be applied to the qualification of the activation level of the dMF and the sMF with specific tasks.

摘要

研究设计

可靠性研究。

目的

调查使用超声测量有和没有下腰痛(LBP)的参与者腰椎多裂肌深层(dMF)和浅层(sMF)厚度的不同测量之间的可靠性。

背景

腰椎多裂肌是维持脊柱稳定性的重要肌肉。dMF被认为在维持强直性收缩和关节稳定性方面很重要。在LBP患者中也发现了运动控制障碍。然而,迄今为止,尚无研究通过超声成像(USI)观察sMF和dMF的方法。

方法

招募了20名年龄在18 - 35岁之间的受试者,其中10名有LBP,10名无LBP。每个受试者在俯卧位以最大等长收缩伸展上躯干。同时,检查者在确定肌腹位置后,使用超声测量dMF和sMF的厚度。参与者在每个测量时段进行3次等长躯干伸展试验,每个时段之间间隔30分钟。测量厚度变化的可靠性用组内相关系数(ICC)表示。

结果

通过对三次测量结果进行平均,在静态或收缩状态下测量dMF或sMF的厚度以及收缩过程中厚度的变化,其可靠性较高(ICC = 0.84 - 1.00)。

结论

已确立了超声成像测量dMF和sMF的测量者内部不同测量之间的可靠性。该方法可应用于通过特定任务来确定dMF和sMF的激活水平。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验