激光蚀刻和镁掺入氧化种植体在兔股骨中的骨整合比较。

Comparison of osseointegration between laser-etched and magnesium-incorporated oxidized implants in the rabbit femur.

机构信息

Department of Prosthodontics, College of Dentistry, Kyung Pook National University, Dae-Gu, South Korea.

出版信息

Int J Oral Maxillofac Implants. 2013 May-Jun;28(3):775-81. doi: 10.11607/jomi.2448.

Abstract

PURPOSE

To compare the osseointegration of a laser-etched (LE) implant with a magnesium-incorporated oxidized (MgO) implant, evaluating their ability to enhance the bond strength between a titanium substrate and rabbit femur.

MATERIALS AND METHODS

Two type of dental implants, LE (test, commercially pure [CP] titanium grade 4) and MgO (control, CP titanium grade 4) (length, 8 mm; diameter, 3.3 mm), were evaluated for the surface characteristics using a field emission scanning electron microscope (FE-SEM), an energy dispersive spectrometer (EDS), and an optical three-dimensional profiling system. After that, two types of dental implants were implanted at the right and left distal femoral metaphysis of 10 adult rabbits weighing approximately 3.0 kg. After 6 weeks, histomorphometric analysis, removal torque tests, and surface analysis of the torque-tested implants were performed.

RESULTS

After surgery, the LE group showed thick bonelike materials within the pores observed using FE-SEM (magnifications ×500 and ×900). The mean removal torque was 40.72 ± 13.3 Ncm for the test (LE) implant and 22.26 ± 6.4 Ncm for the control (MgO) implant, respectively (P = .041). The mean bone-implant contact in the three best consecutive threads in the cortical region was 63.35% ± 16.44% in the LE group and 51.63% ± 5.09% in the MgO.

CONCLUSIONS

In the beginning stage of cancellous bone healing, biomechanical properties of the LE implant could influence a more favorable bone response than that of MgO.

摘要

目的

比较激光蚀刻(LE)种植体和镁掺杂氧化(MgO)种植体的骨整合情况,评估它们增强钛基底与兔股骨之间结合强度的能力。

材料与方法

使用场发射扫描电子显微镜(FE-SEM)、能谱仪(EDS)和光学三维轮廓仪评估两种类型的牙科植入物(LE[测试,商用纯(CP)钛 4 级]和 MgO[对照,CP 钛 4 级])的表面特性(长度 8mm,直径 3.3mm)。之后,将两种类型的牙科植入物分别植入 10 只约 3.0kg 成年兔右侧和左侧股骨远端干骺端。6 周后,对植入物进行组织形态计量学分析、拔出扭矩试验和扭矩试验后植入物的表面分析。

结果

手术后,LE 组在 FE-SEM(放大倍数×500 和×900)观察到的孔隙内显示出较厚的类骨材料。测试(LE)种植体的平均拔出扭矩为 40.72±13.3Ncm,对照(MgO)种植体的平均拔出扭矩为 22.26±6.4Ncm(P=0.041)。皮质区三个最佳连续螺纹中骨-种植体接触的平均百分比,LE 组为 63.35%±16.44%,MgO 组为 51.63%±5.09%。

结论

在松质骨愈合的初始阶段,LE 种植体的生物力学性能可能会影响更有利的骨反应,优于 MgO。