Küçük Levent, Kumbaracı Mert, Günay Hüseyin, Karapınar Levent, Ozdemir Oğuz
Department of Orthopedics and Traumatology, Faculty of Medicine, Ege University, İzmir, Turkey.
Acta Orthop Traumatol Turc. 2013;47(3):153-7. doi: 10.3944/aott.2013.3038.
The aim of this study was to evaluate the interobserver reliability and intraobserver reproducibility of the Universal, AO, Fernandez and Frykman classifications for distal radius fractures.
Fifty standard sets of posteroanterior and lateral roentgenograms of displaced distal radius fractures were classified two times by two groups of evaluators at 2-month intervals. The first group consisted of 10 orthopedic surgeons with a minimum of 5 years of experience. The second group consisted of 10 orthopedic residents in their first two years of practice. Interobserver reliability and intraobserver reproducibility were assessed using Cohen's kappa test.
None of the classifications achieved good- very good reliability levels. The Fernandez classification had a moderate and the others had a fair interobserver agreement kappa coefficient. All classifications had fair kappa intraobserver agreement although the Frykman and Fernandez classifications had better results.
None of the classification systems were superior in terms of reliability and reproducibility. The reliability and reproducibility rates of all four classifications were insufficient.
本研究旨在评估通用型、AO型、费尔南德斯型和弗赖克曼型桡骨远端骨折分类法的观察者间可靠性和观察者内可重复性。
50套标准的移位型桡骨远端骨折正位和侧位X线片由两组评估者进行两次分类,间隔2个月。第一组由10名至少有5年经验的骨科医生组成。第二组由10名从业头两年的骨科住院医师组成。使用科恩kappa检验评估观察者间可靠性和观察者内可重复性。
没有一种分类法达到良好至极优的可靠性水平。费尔南德斯分类法有中等程度的观察者间一致性,其他分类法的观察者间一致性kappa系数为一般。所有分类法的观察者内kappa一致性均为一般,尽管弗赖克曼分类法和费尔南德斯分类法的结果更好。
在可靠性和可重复性方面,没有一种分类系统具有优越性。所有四种分类法的可靠性和可重复性率均不足。