Suppr超能文献

血液样本中储存对氰化物的影响。

The effect of storage upon cyanide in blood samples.

作者信息

Bright J E, Inns R H, Tuckwell N J, Marrs T C

机构信息

Chemical Defence Establishment, Salisbury, Wilts, UK.

出版信息

Hum Exp Toxicol. 1990 May;9(3):125-9. doi: 10.1177/096032719000900301.

Abstract

CDPA blood of human origin was 'spiked' with a solution of potassium cyanide at four different concentrations. When such blood was left in contact with the atmosphere for up to 10 min an appreciable amount of the cyanide was lost. Stoppered tubes containing the 'spiked' blood were stored at -20 degrees C and 4 degrees C for up to 6 months. Most samples, especially those 'spiked' at the highest concentrations, showed a loss of cyanide.

摘要

将来自人类的CDPA血液用四种不同浓度的氰化钾溶液进行“加样”处理。当这种血液在空气中放置长达10分钟时,会有相当数量的氰化物损失。装有“加样”血液的带塞试管在-20℃和4℃下储存长达6个月。大多数样本,尤其是那些“加样”浓度最高的样本,都出现了氰化物损失的情况。